LCX_UserManual_en_08_1.pdf - 第30页
Getting started R&S ® LCX Series 30 User Manual 1 179.2260.02 ─ 08 T able 4-2: Navigation controls Key Assigned functions [Rotary knob] Selects, enables or confirms settings. [ ◀ ] / [ ▶ ] Moves the cursor in the ent…

Getting started
R&S
®
LCX Series
29User Manual 1179.2260.02 ─ 08
Figure 4-5: Touchscreen display
For details on the screen display, see Section 4.4.2.1, "Understanding the display infor-
mation", on page 38.
The touch-sensitive panel provides an alternative means of user interaction for quick
and easy handling of the instrument, see Section 4.4.2, "Means of manual interaction",
on page 37.
4.2.1.2 Keys
This section introduces the functionality of the hardkeys at the front panel. These con-
trols lead you to menus and dialogs displayed on the screen. For information on how to
operate the instrument, see Section 4.4.2, "Means of manual interaction", on page 37.
Basic display keys
The utility keys arrange different windows on the display.
Table 4-1: Display keys
Display key Assigned functions
[home] Returns to the initial feature screen.
[settings] Opens the menu list with general instrument functions.
[★ (User)] Executes a previously assigned user action.
Press and hold opens the favorites menu for assigning a user action.
Navigation controls
The navigation controls include a rotary knob and navigation keys. They allow you to
navigate within the display or within dialogs, see Section 4.4.2, "Means of manual inter-
action", on page 37.
Instrument tour

Getting started
R&S
®
LCX Series
30User Manual 1179.2260.02 ─ 08
Table 4-2: Navigation controls
Key Assigned functions
[Rotary knob] Selects, enables or confirms settings.
[◀] / [▶] Moves the cursor in the entry fields.
[Back] Returns to a previous level in the menus, or closes a view.
Measurement mode keys
The measurement controls enable you to select the measurement mode and view of
the representation of the measurement readings.
Table 4-3: Measurement mode controls
Key Assigned functions
[Meas. Mode] Selects either continuous or triggered measurement mode.
[Display Mode] Selects the display of measurement readings.
Function keys
The keys in the function panel select the parameters for the measurement.
Table 4-4: Measurement function controls
Key Assigned functions
[L] Selects the function for measuring inductance.
[C] Selects the function for capacity measurement.
[R] Selects the measurement for a resistor.
[Transformer] Selects the transformer measurement.
Settings keys
The keys in the settings panel enable you to select measurement ranges and addi-
tional parameters for executing the measurement.
Table 4-5: Measurement function controls
Key Assigned functions
[Freq.] Sets the signal frequency.
[Range] Selects the impedance range.
[Level] Sets the level.
[Comp.] Opens the "Open/Short/Load Correction" dialog for quick access.
[Bias Level] Sets the bias voltage and current.
[Bias Enable] Enables internal or external bias.
Measurement control keys
These keys provide control during the measuring procedure.
Instrument tour

Getting started
R&S
®
LCX Series
31User Manual 1179.2260.02 ─ 08
Table 4-6: Navigation controls
Key Assigned functions
[Auto] Enables the automatic selection of the measurement function.
[Hold] Freezes the measurement range on the screen indicated with the prefix
"Hold:" at the range value.
[Trig.] Triggers a measurement manually.
POWER On/Standby key
The [On/Standby] key switches the instrument from the standby to the ready state or
vice versa.
The [On/Standby] lights green when the instrument is switched on, see Section 4.1.10,
"Switching on or off", on page 27.
4.2.1.3 Connectors
The measurement input connectors and the USB connector are on the front panel.
L CUR, L POT, H CUR, H POT
Four BNC sockets:
●
"L CUR" (low current): signal output for series measurements (signal generator).
●
"L POT" (low potential): signal input for parallel measurement (voltage measure-
ments).
●
"H CUR" (high current): signal input for series measurements (current measure-
ments).
●
"H POT" (high potential): signal input and output for parallel measurements (mea-
surement bridge).
Ground socket
Protective socket (4 mm banana socket) to ground the R&S LCX, e.g. with a grounded
external conductor.
The front panel ground socket is directly connected to the mains safety ground by the
line cord.
See Table 1-1.
USB A
Female USB (universal serial bus) connector of type A (host USB). You can connect a
USB memory stick, e.g., to record and export measurement data, to capture screen-
shots, or to update the firmware.
How to: Section 4.1, "Preparing for use", on page 18
4.2.2 Rear panel tour
This section provides an overview of the connectors at the rear panel of the instrument.
For technical data of the connectors, see the specifications document.