LCX_UserManual_en_08_1.pdf - 第237页
Remote control commands R&S ® LCX Series 237 User Manual 1 179.2260.02 ─ 08 Manual operation: See "Error Beep" on page 135 SYST em:COMMunicate:LAN:ADDRess <Ip address> Sets the IP address. Parameters:…

Remote control commands
R&S
®
LCX Series
236User Manual 1179.2260.02 ─ 08
SYSTem:BEEPer:WARNing:STATe <En-/Disable warning beep>
Activates the R&S LCX to create an acoustic signal on errors and warnings.
The query returns the current state.
Parameters:
<En-/Disable warning
beep>
1 | 0 | ON | OFF
*RST: 1|ON
Example: See Example "General instrument settings" on page 232.
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer:WARNing[:IMMediate]
Activates that the R&S LCX issues a beep on error or warning immediately.
Parameters:
<state> 1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Usage: Event
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer[:COMPlete]:STATe <En-/Disable operation complete beep>
Activates the R&S LCX to create an acoustic signal on a completed operation.
The query returns the current state.
Parameters:
<En-/Disable
operation complete
beep>
1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Manual operation: See "Error Beep" on page 135
SYSTem:BEEPer[:COMPlete][:IMMediate]
Activates that the R&S LCX issues a beep after operation complete immediately.
The query returns the current state.
Parameters:
<boolean> 1 | 0 | ON | OFF
*RST: ON | 1
Example: See Example "General instrument settings" on page 232.
Usage: Event
SYSTem subsystem

Remote control commands
R&S
®
LCX Series
237User Manual 1179.2260.02 ─ 08
Manual operation: See "Error Beep" on page 135
SYSTem:COMMunicate:LAN:ADDRess <Ip address>
Sets the IP address.
Parameters:
<Ip address> Range: 0.0.0.0. to ff.ff.ff.ff
Example: See Example "Network communication settings" on page 234.
Manual operation: See "IP Address" on page 162
SYSTem:COMMunicate:LAN:APPLy
Assigns and confirms the settings.
Example:
See Example "Network communication settings" on page 234.
Usage: Event
SYSTem:COMMunicate:LAN:DGATeway <Gateway>
Sets the IP address of the default gateway.
Parameters:
<Gateway> Range: 0.0.0.0. to ff.ff.ff.ff
Example: See Example "Network communication settings" on page 234.
Manual operation: See "Gateway" on page 163
SYSTem:COMMunicate:LAN:DHCP <En-/Disable DHCP>
Parameters:
<En-/Disable DHCP> ON | OFF | 1 | 0
*RST: OFF | 0
Example: See Example "Network communication settings" on page 234.
Manual operation: See "DCHP & Auto-IP" on page 162
SYSTem:COMMunicate:LAN:DISCard
Removes the LAN configuration.
Usage:
Event
SYSTem:COMMunicate:LAN:EDITed?
Usage:
Query only
SYSTem subsystem

Remote control commands
R&S
®
LCX Series
238User Manual 1179.2260.02 ─ 08
SYSTem:COMMunicate:LAN:HOSTname <Device hostname>
Sets an individual hostname for the R&S LCX.
Parameters:
<Device hostname>
Example: See Example "Network communication settings" on page 234.
Manual operation: See "Desired Hostname" on page 161
SYSTem:COMMunicate:LAN:MAC?
Queries the MAC address of the network.
Example:
See Example "Network communication settings" on page 234.
Usage: Query only
Manual operation: See "MAC Address" on page 163
SYSTem:COMMunicate:LAN:RESet
Terminates the network configuration and restarts the network.
Example:
See Example "Network communication settings" on page 234.
Usage: Event
Manual operation: See "Reset LAN Conection" on page 163
SYSTem:COMMunicate:LAN:SMASk <Subnet mask>
Sets the subnet mask.
Parameters:
<Subnet mask>
Example: See Example "Network communication settings" on page 234.
Manual operation: See "Subnet Mask" on page 163
SYSTem:COMMunicate:NETWork:VNC:PORT <Port>
Sets the VNC port address.
Parameters:
<Port> Range: 100 to 65535
*RST: n.a. (factory preset: 5900)
Example: See Example "Network communication settings" on page 234.
Manual operation: See "VNC Port" on page 164
SYSTem subsystem