YSi-SP_Ope_E.pdf - 第20页

1-4 1 Over view and maintenance of machine 3.3 Installation T he space of the machine's bac kward and forward should be ensured as 700mm and o ver for using and maintenance. 3.3.1 Level adjustment T he frame of the …

100%1 / 147
1-3
1
Overview and maintenance of machine
3. Before Use
3.1 Power supply specifications
Power supply specifications Single-phase AC 200V to 230V±10%
Frequency 50/60Hz±1Hz
Power cable specifications 3-wire type (with earth), Conductor cross section area 20mm
2
or more (with 10A breaker)
3.2 Caution items when installing
Power supply connection construction
w
WARNING
ONLY PERSONS QUALIFIED IN ELECTRICAL WORK CAN MAKE POWER SOURCE CONNECTIONS. DO NOT TOUCH THE
MOVING AREA DURING PRODUCTION OPERATION.
FAILURE TO OBSERVE THIS WARNING MAY CAUSE LIFE-THREATENING SERIOUS ACCIDENTS SUCH AS ELECTRIC SHOCK
ACCIDENTS OR FIRE.
PROVIDE THE THIRD TYPE GROUNDING TO PREVENT ELECTRIC SHOCK AND MALFUNCTION.
Installation location
c
CAUTION
Do no use this machine in any place where there is dust, oil, smoke, electrical conductivity dust, corrosive gas, or
combustible gas, or where it is high temperature, condensation occurs, or it is exposed to the weather.
This may cause failure, malfunction, or deterioration.
Transfer with a forklift
w
WARNING
ONLY QUALIFIED PERSON CAN OPERATE THE FORKLIFT.
DO NOT PUT YOUR BODY UNDER LIFTED MACHINES FOR ANY REASON. CENTER OF GRAVITY IS REFERRED TO "4. 1 MACHINE
SPECIFICATION".
n
NOTE
When there are co-workers, determine a work leader and work according to the instruction.
In this case, observe the following:
Ensure to give sings and be sure to check the sign each other.
Give a sign step-by-step.
Use inspected transport equipment (forklifts), which sufficiently supports weight.
1-4
1
Overview and maintenance of machine
3.3 Installation
The space of the machine's backward and forward should be ensured as 700mm and over for using and
maintenance.
3.3.1 Level adjustment
The frame of the machine is supported by four leveling bolts.
Adjust them at the same height as the following figure.
In addition, be sure to use a level to adjust the level.
Leveling bolt
The cable clamp for
power source wire fixation
Level setting place
(Level setting place)
M30 4 places
φ60
100
Leveling bolt
Power source wire course
Power source wire intake
(Lower machne)
23102-KMN-00
Operating precautions
1. Ensure to connect the power cable.
2. Please fix a cable using a cable clamp for cable protection. (Refer to above figure)
3. Be sure to turn off the breaker on the power source side when you do not use the machine for a long time.
4. Do not put other things into the operating part or apply vibration while the machine is running.
1-5
1
Overview and maintenance of machine
4. Machine Overview
This machine automatically inspects the printed condition of cream solder (area, height) printed on boards by
the image processor.
Measure the position correction mark of the board that took in through a conveyor belt, and based on that,
image process the print state per field of view at the inspection speed of MAX 0.27 sec/visual field.
4.1 Mechanical specification
Standard type Extension conveyor unit type
Board size (L*D*H)
(Tower light is not included.)
904×1080×1478mm
One side extension type :
1484×1080×1478mm
Both sides extension type :
2
064×1080×1478mm
Path line height 900±20mm
Machine weight pprox. 520kg
One side extension type :
pprox. 555kg
Both sides extension type :
pprox. 590kg
Power consumption 1000W or less
Power supply
Single-phase AC 200V to 230V ± 10%
50/60Hz ± within 1Hz
Electric capacity 1.0kVA (Max)
Mechanical specification
Path line
Center of Gravity
Center of Gravity
Front view Right side view
904 1080
1850
1478
900 ± 20
100
347460
23103-KMN-00