YSi-SP_Ope_E.pdf - 第90页
2-53 2 Operation 3.6.13 CSV Auto Output Per PCB Items displa yed on the CSV Auto Output P er PCB ,and functions are described. 1 2 24271-KMN-00 ■ Explanation of a screen No Name Content 1 Use Auto Output Per PCB Place ch…

2-52
2
Operation
3.6.12 Maintenance display
Setting up for announce display and updating for coming replace timing on the maintenance screen.
1
2
3 4 5 6
7
8
24270-KMN-00
No Name Description of displayed item and functions
1 List tab
Displaying for the registered maintenance parts.
• List Tab1 : Displaying the registered parts from No. 1 to 10.
• List Tab2 : Displaying the registered parts from No. 11 to 20.
• List Tab3 : Displaying the registered parts from No. 21 to 30.
2 Announcement Switching ON/OFF of message display.
3 Name Displaying the parts name should be replaced.
4 Type Displaying the parts type should be replaced.
5 Effective years Displaying the parts replace interval.
6 A next exchange day Displaying the coming replace date.
7 Update button
Updating next parts replace date.
This button shall be selected after the maintenance parts are replaced.
In case of selection g the button, “Selected current date + Valid Date”
shall be displayed the coming replace date.
8 Explanation of a button color
The rest date to coming replace interval shall be with the colored buttons.
• Green : The coming replace date is more than one month.
• Yellow : The coming replace date is in one month.
• Red : The coming replace date is in one week.
The maintenance parts displayed with yellow and red colored buttons are in the
announce condition.

2-53
2
Operation
3.6.13 CSV Auto Output Per PCB
Items displayed on the CSV Auto Output Per PCB ,and functions are described.
1
2
24271-KMN-00
■
Explanation of a screen
No Name Content
1 Use Auto Output Per PCB Place check mark for use auto output per PCB.
2 Change Set Changing the setting for CSV output.
1
2
3
4
5 6
24272-KMN-00
■
Explanation of a screen
No Name Content
1 Line name Setting up the line name for CSV output.
2 Machine name Setting up the machine name for CSV output.
3
Directory set Displaying the directory for CSV output.
[Reference] button Changing the directory for CSV output.
4 Confirmation of Capacity of disk When it approaches full up the capacity, the error message is displayed.
5 [OK] button Execution of setting.
6 [Cancel] button Canceling the setting.

2-54
2
Operation
3.6.14 Screen of function restriction for Operator
Select according to the procedure as [Function/Setting]
→
[Disp Relation] in Main display, and push [Function
Restriction] for Operator, then the pop-up of Function Restriction for Operator is displayed.
3
4
5
1 2
24273-KMN-00
No Description Description of displayed item and functions
1 [OK] button Execution of setting.
2 [Cancel] button Canceling the setting.
3 Do not show the path mode.
When checked, Pass mode does not appear in the pull-down menu of
inspection mode under the log-in as Operator.
4
Request the password of engineer at
the start of pass mode
When checked, the password request message for Engineer Authority is
displayed at the start of Pass mode inspection.
5 Do not show the manual judgment.
When checked, when you login the operator, Manual Judge-related
display does not appear.