YSi-SP_Ope_E.pdf - 第25页
1-9 1 Over view and maintenance of machine 4.4 W ork size which can be inspected by this machine ■ W ork size Outline (L * W) 50 * 50 to 510 * 460 mm Weight (MAX) 3.0 kg or less Board thickness 0.3 to 5.0 mm 4.5 Conditio…

1-8
1
Overview and maintenance of machine
4.3 Name of each part
Name of each part
Tower light
XY unit
Camera
Treatment
cone
Z-axis light
source unit
Z-axis offset
XY unit
LED
illumination
Conveyor
Emergency stop button
Operation panel
Keyboard
Breaker
Control panel
Control PC
23105-KMN-00
Name of each part
YSi-SP Extension conveyor unit type (option)
Extension Conveyor unit
Extension Conveyor unit
23113-KMN-00

1-9
1
Overview and maintenance of machine
4.4 Work size which can be inspected by this machine
■
Work size
Outline (L * W) 50 * 50 to 510 * 460 mm
Weight (MAX) 3.0 kg or less
Board thickness 0.3 to 5.0 mm
4.5 Conditions of work shape
■
Conditions of work shape
Warp of the work
Short
interval
0.3/40 mm or less
Fluctuation
of the entire
interval
±5.0 mm or less
Height of cream solder (MAX)
400 μm or less (Resolution: at 25 um/12.5 um)
300 μm or less (Resolution: at 20 um/10 um)
300 μm or less ((Resolution: at 15 um/7.5 um)
Material and
color of board
Material of
substrate
Glass epoxy, paper phenol, polyimide film base
*Consult with CKD for alumina (ceramic) substrate.
Solder resist
color
Solder resist color shall not be dark color like black.
Consult with CKD for light color.
4.6 Operating environment
■
Operating environment
Room temperature 25 °C to 35 °C (68 °F to 95 °F)
Humidity 50% to 70% (without condensation)
Altitude Average altitude 1000 m or less
Overvoltage section III
Pollution level 3
4.7 Noise value
65dB (A)
Operating Condition : Full load Measuring Method : According to clause 1. 7. 4. 2 of Machinery Directive
2006/42/EC
4.8 Transportation, storage environment
By design or by taking proper preventive measure, electrical equipment can withstand the influence of
temperatures for the transportation and storage temperatures from -25 °C to + 55 °C (-13 °F to 131 °F).
Appropriate measures must be taken to protect the equipment from damages by humidity, vibration, and
impact.
4.9 Rules for design reference
Machinery Directive:
EN ISO12100, EN ISO13849, EN 60204-1, EN ISO13857 etc

1-10
1
Overview and maintenance of machine
5. Temporary measure for PLC/UPS failure
This section describes the temporary measure for PLC/UPS failure.
5.1 Pass Mode of PLC
In this machine, a reserve HDD (Hard disk drive) and UPS (Uninterruptible power source) are equipped as
standard, and a prompt restoration is possible in case of momentary power outage and HDD failure.
However, in case of personal computer failure, it is possible to continue pass transfer (PASS mode) by PLC
(programmable logic controller) for substrate transfer control alone.
5.1.1 PLC switch panel
The PLC switch panel is located when the keyboard table is opened. It is usually not used. Use the switch
when your personal computer does not operate due to the personal computer failure of machine’s main body.
Switch panel
1
23
Reset / Stop / Start
23106-KMN-00
Machine name Motion and check
1 [Start] button Starts the PASS mode.
2 [Stop] button Stops the PASS mode.
3 [Reset] button Reset the home position.