4 Single Functi ons SIPLACE 80S-20/F4/F4-6 User’s Manual 4.3 Single Functions, Gantry with 6x Revolver Head (for 80F4-6) Edition 07/ 97 from Software Version SR.403.xx 4 - 34 4.3.4 Vacuum Test, 6x Revolver Head If all no…

100%1 / 744
SIPLACE 80S-20/F4/F4-6 User’s Manual 4 Single Functions
Edition 07/97 from Software Version SR.403.xx 4.3 Single Functions, Gantry with 6x Revolver Head (for 80F4-6)
4 - 33
4.3.3.4 Head Reference Run
When this function is activated, the z and d axes will carry out a reference run.
Within the working area click on the Head reference run button. The z and d axes will carry out a refer-
ence run.
4.3.3.5 Turn D Axis
When this function is activated, you can check the d axis. For the check the d axis is rotated.
Within the working area click on the Turn d axis button. The d axis will rotate.
4.3.3.6 Z Axis - Unclamp
When this function is activated, clamping of the z axis will be released.
Within the Z axis working area click on the Unclamp button. The clamping of the z axis is released and a
message window appears.
To activate clamping click on the OK button. The message window will be closed and clamping of the z
axis is active.
4.3.3.7 Vacuum - On
When this function is activated, the vacuum is switched on.
Within the Vacuum working area click on the On button. The vacuum will be switched on.
4.3.3.8 Vacuum - Off
When this function is activated, the vacuum is switched off.
Within the Vacuum working area click on the Off button. The vacuum will be switched off.
4.3.3.9 Forced air - On
Activate this function to switch on the forced air to the nozzle. If it is active, the vacuum will be switched off at
the same time.
Click on the On button in the Forced air work area. The forced air will be switched on.
4.3.3.10 Forced air - Off
Activate this function to switch off the forced air to the nozzle.
Click on the Off button in the Forced air work area. The forced air will be switched off.
4 Single Functions SIPLACE 80S-20/F4/F4-6 User’s Manual
4.3 Single Functions, Gantry with 6x Revolver Head (for 80F4-6) Edition 07/97 from Software Version SR.403.xx
4 - 34
4.3.4 Vacuum Test, 6x Revolver Head
If all nozzles are at the star, when this function is activated the nozzles will be checked regarding their vacuum
values in the pick-up position.
In the Gantry functions menu click on the symbol button for Vacuum test revolver head.
Fig. 4.3.6 Vacuum test 6x revolver head
Click on the Measure button. A head reference run will be carried out and the vacuum values at the pick-
up position measured for all nozzles. The measured values for the open and closed pick-up positions are
displayed.
F
SIPLACE 80S-20/F4/F4-6 User’s Manual 4 Single Functions
Edition 07/97 from Software Version SR.403.xx 4.3 Single Functions, Gantry with 6x Revolver Head (for 80F4-6)
4 - 35
4.3.5 Nozzle Offset, 6x Revolver Head
This function is used for determining the nozzle height of all segments. If all segments are in the star the value
found here will refer to Segment 1.
In the In the Gantry functions menu click on the symbol button for Nozzle offset revolver head.
Fig. 4.3.7 Nozzle offset 6x revolver head
Click on the Measure button.
Press the Start button when you are asked to do so on the screen. The active gantry will move to a defined
position above the board conveyor and there carry out measurement of the z height with all segments.
Once measurement is finished the gantry will return to its starting position. The measured nozzle heights
will now be displayed.