9 Maintenance SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
9.5 12x Revolver Head 10000 Edition 03/98 from Software Version SR.404.xx
9 - 50
9.5.2.3 Sleeve Vacuum Test
In the Main view menu click on the Gantry 1 functions or Gantry 2 functions menu.
Click on the Vacuum test revolver head menu.
Click on the Measure button.
For all sleeves the vacuum figures are measured for Nozzle opened and Nozzle closed in the pick-up
position. The pairs of values so measured will be displayed in tabular form on the screen, arranged by seg-
ment numbers.
9.5.2.4 Cleaning Sleeve and Segment
Tools and Consumables
Lint-free, clean cloth
Metal drill, diameter 1.2 mm and 1.4 mm
Plastic brush, diameter 6 mm, from item no. 00325929-01
White laboratory gloves
Segment maintenance cloth, from item no. 00315253-01
Clean sleeve and segment at least every four weeks. If you do not do so, vacuum conditions at the sleeve will
be impaired.
Remove the sleeve, as described in Section 9.5.2.1 on page 9 - 49.
Wipe the annular surfaces (A) and the grooves of the sleeve (see Fig. 9.5.3) with a lint-free cloth. Wet the
plastic brush with the cleaning agent of the segment maintenance cloth. In addition carefully clean the
annular groove (F) of the vacuum duct with the plastic brush.
Remove dirt remnants from the vacuum duct hole (B) of the sleeve with the 1.4 mm metal drill.
Use the 1.2 mm diameter metal drill to remove remnants of dirt from the transverse vacuum duct hole (E).
Clean the reflective face (G) of the sleeve with a cloth soaked in ethyl alcohol.
Wet the plastic brush with the cleaning agent of the segment maintenance cloth and use it to clean the
hole in the segment (D).
Insert the sleeve in the segment again.
NOTE
Make sure that annular braking surface (C) on the sleeve is free of oil, otherwise there may be rotational
errors.
Carry out a vacuum test (see Section 9.5.2.3, Page 9 - 50).
- Key to Fig. 9.5.3
1Sleeve
2 Segment
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 9 Maintenance
Edition 03/98 from Software Version SR.404.xx 9.5 12x Revolver Head 10000
9 - 51
- Sequence of work in Fig. 9.5.3
A Clean the annular surfaces and grooves of the sleeve.
B Clean the longitudinal vacuum hole of the sleeve using the 1.4 diameter metal drill.
C Make sure that the annular braking surface is free of oil.
D Clean the segment hole with the plastic brush and the cleaning agent of the segment maintenance cloth.
E Clean the transverse vacuum duct hole with the 1.2 diameter metal drill.
F Clean the groove with the plastic brush and the cleaning agent of the segment maintenance cloth.
G Clean the reflective face of the sleeve with ethyl alcohol.
H Keep the drive faces of the sleeve dry and free of grease.
Fig. 9.5.3 Cleaning sleeve and segment of the 12x revolver head
B
D
1
2
1
G
F
C
H
A
E
A
9 Maintenance SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
9.5 12x Revolver Head 10000 Edition 03/98 from Software Version SR.404.xx
9 - 52
9.5.2.5 Replacing the Snap O-Ring in the Sleeve
Materials and Equipment
A clean and lint-free cloth
Unisilkon L250L, from item no. 00310259-01
White laboratory gloves
Pointed tweezers or smallest watchmaker’s screwdriver
Spare Part
Snap o-ring sleeve, from item no. 00323535-02
Fig. 9.5.4 Replacing the snap o-ring in the sleeve
- Key to Fig. 9.5.4
1Sleeve
2 Annular groove
3 O-ring
4Nozzle
Remove the sleeve as described in Section 9.5.2.1 on page 9 - 49.
Pull the nozzle off the sleeve (A).
Insert pointed tweezers or a watchmaker’s screwdriver between the o-ring and the annular groove and
lever off the o-ring (B).
Grease the new o-ring with Unisilkon and insert it into the annular groove (C).
,
C
B
A
4
3
2