7.1 Error Information
If errors occur while the board is being processed you will be able to access information on the errors in ques-
tion. The relevant error information can be accessed from both the Main view menu and from Display errors.
7.1.1 Procedure
If an error occurs while the board is being processed and is shown in the status window.
Click on the Error information button.
Fig. 7.1.1 Example of an error message
The following window will be displayed:
7 Error Information & Diagnostics SIPLACE 80S-20/F4/F4-6 User’s Manual
7.1 Error Information Edition 03/98 from Software Version SR.403.xx
7 - 4
Fig. 7.1.2 Example of the corresponding error information
- Key to Fig. 7.1.2
1 Remedy with additional information on the cause of the error (text in green) .
Click here to obtain further information.
2 Remedy without additional information (text in blue).
3 Possible cause of the error in question (text in black).
4 The error which has occurred, with error number (text in red).
5 Symbol of the error type (machine error, track error, and so on).
NOTE
Different colors are used for differentiating the significance of the texts (cause, remedy).
The black text indicates possible causes of the fault which has occurred. The corresponding remedy is shown
beneath this, as blue or green text.
Click on the green text. Additional information on correcting the cause of the error will also be displayed.