SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functi on s Edition 03/98 from S oftware Version SR.404.xx 5.5 Teach Fiducial Line engi neer 5 - 47 5.5.3 Select Fiducial Menu When the Teach fiduci al option i n the Main…

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 46
Menu Options ’Teach fiducial’, Part 2
’Test fiducial’ menu
ESC
Yes
Test fiducial
Fiducial
loaded or
tought?
A
’Select fiducial
menu
ESC
Center TestPCB to center conveyorMove X/Y axes PCB to output conveyor
Positioning Fiducial
Video image
Position
camera
PCB transport
Video image
Define
template
window
(hor./vert.)
Video image
Triggering
measurement
sequence; output
fiducial quality
No
Return
(Save)
’Contrast sensitivity’ menu
Accept
(Save programmed
values)
Yes
Contrast sensitivity
Fiducial
loaded or
tought?
A
’Select fiducial
menu
ESC
Program
transform 5
Fiducial
Video image
Teach command with different
grey-scale transformation
Output of uniqueness
No
Transform 1 Transform 2 Transform 3 Transform 4 Transform 5
ESC Return
(Repeat)
Program sensitivity
of transform 5
Standard values
(Accept standard
values)
Cancel
Option box
’Program sensitivity
of transform 5’
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 47
5.5.3
Select
Fiducial
Menu
When the Teach fiducial option in the Main view menu is selected the following actions will be started:
The functions for the vision system are activated in the station computer
The Select fiducial menu will drop down.
The station computer asks the line computer for the list of fiducial numbers with commentaries and dis-
plays them on the screen. The transformation tables for the screen colors are held locally in the station
computer.
Fig. 5.5.2 Select fiducial menu
As the diagram shows, the menu offers the following options for selection.
Select gantry
Load fiducial
Define new fiducial
Change fiducial name
Save fiducial
Fiducial numbers list
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.5 Teach Fiducial Edition 03/98 from Software Version SR.404.xx
5 - 48 Line engineer
NOTE
Buttons are active when the text on the button is black (rather than gray). This means that you can launch the
associated function by clicking on the button with the mouse.
The Load fiducial button will, for example, only be active if you have previously clicked on a fiducial in the
lists field.
The Change fiducial name button will only be active if you have loaded a fiducial and the Save fiducial but-
ton will only be active if you have either changed the fiducial name or fiducial parameters.
You can switch from the ’Teach fiducial’ menu to the Main menu at any time in order to start actions such as
"Fill track“ etc. The settings in the ’Teach fiducial’ menu will be retained, which means that the same condi-
tions will be set up when you return to the ’Teach fiducial’ menu.
However, if you have changed fiducial data or taught a new fiducial, and then switch from the Main menu to
the ’Test component’, ’Single functions’, ’SITEST’ or ’Continue placement’ menu, the ’Save fiducial data’
selection box will appear when you leave the ’Teach fiducial’ option. You can then either save the modified or
new data or delete it.
Fig. 5.5.3 Select fiducial menu, Save fiducial data option box