80S-2080F480F4-680F5 User’s Manual.pdf - 第376页
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functi on s Edition 03/98 from Software Version SR.404.xx 5.9 Teach Fiducial: Additions with t he 80F4, 80F4-6 or 80F5 Machines Line engi neer 5 - 155 5.9 Teach Fiducial :…

5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.8 Recommendation for visually centering components Edition 03/98 from Software Version SR.404.xx
5 - 154 Line engineer
5.8.4 Visually centering flip-chips
5.8.4.1 Setting the parameters on the station computer
Under the ’Illumination’ option in the ’Test component’ menu, select:
– a value of around 50 for the medium illumination plane
– a value of around 20 for the steep illumination plane
5.8.4.2 Recommended sequence of measurements for visually centering bare dies
Measuring mode Size Grid Ball
Settings
Resolution in the measuring direction:
very high
——
Resolution in the integration direction:
very high
——
Tab. 5.8.3 Recommended sequence of measurements for visually centering bare dies

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.9 Teach Fiducial: Additions with the 80F4, 80F4-6 or 80F5 Machines
Line engineer 5 - 155
5.9
Teach Fiducial
: Additions with the 80F
4
, 80F
4
-6 or
80F
5
Machines
In contrast to the 80S-20 placement machine the 80F
4
, 80F
4
-6 or 80F
5
machine is a single-gantry machine.
For this reason in the Teach fiducial menu the Select gantry option is permanently set to Gantry 1. The
Gantry 2 option cannot be clicked on.
The IC placement head is mounted on the gantry, together with the 12x revolver placement head on the 80F
4
and the 6x revolver placement head on the 80F
4
-6 and 80F
5
automatic placement machines. The camera
system for board centering is accommodated on the gantry underside.
All menus with the exception of this option are identical to those of the 80S-20 machine.
A description of the menus and their options will be found in Section 5.5 from Page 5 - 43.
Fig. 5.9.1 Select fiducial menu, Select gantry option
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.9 Teach Fiducial: Additions with the 80F4, 80F4-6 or 80F5 Machines Edition 03/98 from Software Version SR.404.xx
5 - 156 Line engineer