80S-2080F480F4-680F5 User’s Manual.pdf - 第20页

0 Introduction SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 0.2 Technical Data Edition 03/98 from Software Vers ion SR.404.xx 0 - 16 0.2.2.8 Machine control 0.2. 2.9 Compresse d Air Sp ecifi cation 0.2.2.1 0 Noise Em ission V…

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 0 Introduction
Edition 03/98 from Software Version SR.404.xx 0.2 Technical Data
0 - 15
0.2.2.5 Connection and Installation Data
0.2.2.6 Machine Dimensions
0.2.2.7 Permissible Environmental Influences
Connection and installation data
System voltage 230/400 V ± 10 % (50/60 Hz)
System voltage (option for USA) 110/208 V ± 10 % (50/60 Hz)
Total connected load 5 kVA
Total power consumption 5 kW
Fuse protection 3 x 16 A
Compressed air supply Min. 5.5 bar / max. 10 bar
Entire compressed air consumption 250 NL/min.
Machine footprint
Permissible surface load > 1000 kg/m
2
Machine dimensions
Weight base module 1500 kg
Weight fully-equipped Approx. 2000 kg
Length 1587 mm
Width 2425 mm
Height with warning light 1836 mm
Permissible environmental influences
Room temperature
Between 15
o
C and 35
o
C
Air humidity
30 to 75 %
(on average not higher than 45%, so that under no circum-
stances will there be condensation in or on the machine)
0 Introduction SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
0.2 Technical Data Edition 03/98 from Software Version SR.404.xx
0 - 16
0.2.2.8 Machine control
0.2.2.9 Compressed Air Specification
0.2.2.10 Noise Emission Values
Machine control
Computer machine controller
PC 486
RMOS operating system
Computer station control
Pentium PC
MS-Windows NT 4.0 operating system
Machine control Siemens S5 input/output control
Axis controller Siemens axis controller boards (digital)
Compressed air specification
Max. particle size by density, based on ISO/DIS 8573-1 (Class 1)
Particle size 0.1 µm
Particle density
0.1 mg/m
3
Max. oil content (Class 1)
Particle density 0.01 mg/m
3
Pressure dewpoint (Class 4)
Dewpoint +3
o
Noise emission values specified in accordance with DIN 45 649-1
Emission value at a workstation (L
pAc
) 71 dB (A)
DIN EN ISO 11204 (i)
Sound power level (L
WAc
) 85 dB (A)
E-DIN EN ISO 3744 (i)
001-0307
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 0 Introduction
Edition 03/98 from Software Version SR.404.xx 0.2 Technical Data
0 - 17
0.2.3 Siplace 80F
4
- 6
0.2.3.1 Gantry Axis
0.2.3.2 6-nozzle Revolver Head
Gantry axis
Drive D.C. servo motors
Path-measuring system Linear incremental scales
Resolution x/y axes 2.5 µm
Speed x axis 2.0 m/s
Speed y axis 2.0 m/s
6-nozzle revolver head
Programmable placement force (z axis) 2.0 N to 5.0 N
Nozzle types 24 (70x, 71x, 72x, 75x, 8xx)
Segments 6
Components that can be assembled
Max. height 6.0 mm
Min. pitch 0.5 mm
Dimensions: 1.5 mm x 0.75 mm to 32 mm x 32 mm
Weight up to 5 grams
Resolution dp turning axes
0.0125
o
Resolution star axis
0.0025
o
Stroke z axis Max. 16 mm