SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options Edition 03/98 from Software Version SR.404.xx 11.12 Nozzle Changer for the 6x Revolver Head 11 - 87 11.12.4 Notes on Operation Before filling a ma gaz…

11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
11.12 Nozzle Changer for the 6x Revolver Head Edition 03/98 from Software Version SR.404.xx
11 - 86
l Returning a nozzle
- The locking plate opens.
- The z-axis moves down.
- The locking plate closes.
- The z-axis moves down.
Fig. 11.12.3 Position of the locking plate
- Key to Fig. 11.12.3
1 Locking plate
l Rejection of defective nozzles
- The z-axis travels a distance of 14 mm at the reject position.
- The z-axis moves up and the nozzle is removed from the sleeve by spring wires.

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options
Edition 03/98 from Software Version SR.404.xx 11.12 Nozzle Changer for the 6x Revolver Head
11 - 87
11.12.4 Notes on Operation
Before filling a magazine with a specific nozzle type, attach an adhesive label with the designation of the
nozzle type to the magazine.
PLEASE NOTE
Although various nozzle types from the same family (7.xx or 8.xx) can be used and configured for each mag-
azine, this should be avoided in order to prevent the machine being set up incorrectly.
Fill the magazines off the machine and only ever replace complete magazines.
Open the locking plate and insert the nozzles in the nozzle garages.
Close the locking plate so that the nozzles cannot fall out of the magazines.
Magazines must only be filled if all the nozzles on the revolver head have been returned to the magazine.
If you want to use different functions of the nozzle changer, see section 4.2.6 and section 4.2.7 of this User
Manual.
See the User Manual for the UNIX line computer for programming the nozzle changer on the line com-
puter.
PLEASE NOTE
Do not allow components to fall onto the magazines. This can cause the locking plate to jam. Do not allow
components to fall onto free locations since this will prevent magazines being set down precisely on these
locations. Remove all components from the magazines and free locations on a regular basis.

11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
11.12 Nozzle Changer for the 6x Revolver Head Edition 03/98 from Software Version SR.404.xx
11 - 88
11.12.5 Emptying the Reject Container
The capacity of the reject container is approximately 50 nozzles from nozzle family 7xx and approximately 5
nozzles from nozzle family 8.xx. To prevent faults during placement, you must regularly empty the reject con-
tainers.
Fig. 11.12.4 Emptying the reject containers
- Key to Fig. 11.12.4
1 Removing reject containers
Pull the reject container out of the holder in the direction of the arrow and lift the reject container out of the
support.
To use the reject container again, push it back into the holder.