80S-2080F480F4-680F5 User’s Manual.pdf - 第264页
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functi on s Edition 03/98 from S oftware Version SR.404.xx 5.5 Teach Fiducial Line engi neer 5 - 43 5.5 Teach Fiducial 5.5.1 Teach Fiducial Flow Chart The Teach fiduci al …
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.4 Access to the Teach Fiducial and Test Component Options Edition 03/98 from Software Version SR.404.xx
5 - 42 Line engineer

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 43
5.5 Teach Fiducial
5.5.1
Teach Fiducial
Flow Chart
The Teach fiducial flow chart shows in graphic form all menu options together with their sub-functions. The
menus are indicated by being bordered with an solid line, while the option boxes use a dash-dotted line and
the input boxes a center line.
To flow chart "Teach fiducial“ part 1 and part 2
5.5.2 Information on the Flow Chart
5.5.2.1 Menus
The Teach fiducial option includes the following menus:
– Select fiducial
– Teach fiducial
– Contrast sensitivity
– Test fiducial
The Save fiducial data option box will be displayed each time you quit the Teach fiducial option after having
created or modified fiducial data. You are thus given the choice of saving these fiducial parameters or of dis-
carding them.
You can quit the individual menus by clicking on either the icon of another menu or on the Main view icon.
5.5.2.2 Input Boxes, Option Boxes
The system provides the following input boxes for entering data, for displaying values and for executing
actions:
– Define new fiducial
– Change fiducial name
– Program transform 5
You can quit the input boxes with OK, Accept or Cancel.
– Click on OK or Accept with the mouse and the data will be transferred to the program and saved. The
input box closes.
– Click on the Cancel button and the data will be discarded and the input box closed.
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.5 Teach Fiducial Edition 03/98 from Software Version SR.404.xx
5 - 44 Line engineer
5.5.2.3 Buttons
For selecting options the system provides the following buttons:
– Select the teaching gantry
Use the mouse to select the teaching gantry.
– Save fiducial
The fiducial parameters just generated will be saved when you click on this button.
– Load fiducial
Once you have selected the desired fiducial from the lists field, click on the Load fiducial button. The fidu-
cial parameters will be loaded.
5.5.2.4 Video Images
With certain actions the camera image of the MVS system (vision evaluation unit) is displayed on the screen
of the station computer. In addition the screen will include header and footers:
– The header includes, for example, the currently selected menu option, the fiducial number, evaluation cri-
teria, measurement results and so on.
– The footers include command sequences, keyboard commands, camera coordinates and so on.
You can always quit displays of video images with the ESC key. The corresponding menu window will then
reappear.
5.5.2.5 Warning and Message Boxes
Messages are text fields which contain information regarding actions, warnings and so on. They will appear
under the following circumstances:
– incorrect operator actions (for example, a board still on the center conveyor).
– requests to the operator to carry out certain actions (for example, remove board).
– instructions (for example, input the name of a fiducial).
– to indicate the system is busy performing an action (for example, loading fiducial data).