1 Operational Safety SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
1.1 Information on safety Edition 03/98 from SW SR.404.xx
1 - 10
Fig. 1.1.7 Label: ‘Laser radiation...’
Fig. 1.1.8 Label: ’Caution ...’
1.1.8 Safety instructions for changing the component table
Changing the component table is described in section 10.3 “Component tables“. Always obey the following
safety instructions to prevent injury or damage to the automatic placement system.
WARNING
When you change the component table, always follow the sequence for removing the plugs from the commu-
nication unit and then connecting them again as described below. If you do not follow the specified order,
faults may occur in the component table.
WARNING
Move the portal out of the range of the component table over the PCB transport. This will prevent the possibil-
ity of a head crash.
DANGER
Press the emergency stop button. The gantry axes are switched off and isolated.
This will prevent the gantries starting up accidentally, thus preventing the associated risk of injury or damage.
Laser radiation
Do not look into the beam
Laser class 2
Caution
Laser radiation if the cover is opened
and the safety interlock is bypassed
Do not look into the beam
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 1 Operational Safety
Edition 03/98 from SW SR.404.xx 1.1 Information on safety
1 - 11
1.1.9 Safety instructions for opening the protective covers
To prevent any risk of injury when the protective covers on automatic placement machines are opened, the
owner must instruct his operators to use the protective covers exactly as specified in the following description.
RISK OF TRAPPING FINGERS IF THE PROTECTIVE
COVERS ARE OPENED OR CLOSED INCORRECTLY
When you open the protective covers, if you place one hand in one of the recessed grips (1) and place the
other hand on the protective cover in order to guide it (item (5) in Fig. 1.1.9), you risk trapping your fingers in
the narrow gap (4) between the monitor traverse (3) and the protective cover (2).
Fig. 1.1.9 Protective covers on the SIPLACE automatic placement machine
- Key to Fig. 1.1.9
1 Recessed grips for opening and closing the protective covers
2 Protective cover
3 Monitor traverse
4 Narrow gap (between 4 and 10 mm) between the monitor traverse and protective cover
5 Do NOT place your hand on this surface!
1 Operational Safety SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
1.1 Information on safety Edition 03/98 from SW SR.404.xx
1 - 12
Every protective cover on the automatic placement machine has two recessed grips (1).
PLEASE NOTE
Always place both hands in these recessed grips (see point (1) in Fig. 1.1.10) in order to open or close the
protective covers. This “two-handed operation” will prevent any risk of injuring your hands.
You will also avoid tilting the protective covers during opening or closing, which would place an excessive load
on the guides.
Fig. 1.1.10 Two-handed operation
- Key to Fig. 1.1.10
1 Two-handed operation