80S-2080F480F4-680F5 User’s Manual.pdf - 第591页

10 Component Handling SIPLACE 80 S20/F4/F4-6/F 5 User’s Manual 10.10 Surf tape feeder module (applies to 80F5 wi th DCA option only) E dition 03/98 from Software Version SR.404.xx 10 - 38 etc. up to: \ Gehaeu seform 100 …

100%1 / 744
SIPLACE 80 S20/F4/F4-6/F5 User’s Manual 10 Component Handling
Edition 03/98 from Software Version SR.404.xx 10.10 Surf tape feeder module (applies to 80F5 with DCA option only)
10 - 37
Settings for the individual values:
Meaning:
Settings:
\ *** Maschinendaten Surftape-Feeder *** \
\ Datei "DCA.MA"| File name none
\ Version \ "8.404.03"| Current version none
\ Maschinentyp \ "80F4"| Machine type 80S4 or 80F4 none
\ *** Schalteroptionen 0/1 *** \
\ Surftapeablauf ein/aus \ 1, Special surf tape sequence 0:off, 1:on *1)
\ immer Bestueckzeit fuer Listen-GF \ 0, Placement wait time for PF specified below 0:off, 1:on *1)
\ Kraftstufe beim Abholen mit SP-Kopf\ 0, Z axis values from power record 0:default, 14:pwr stage 14 *2)
\ Kraftstufe beim Abholen mit IC-Kopf\ 0| Z axis values from power record 0:default, 14:pwr stage 14 *2)
\ *** Feederdaten-Array *** \
\ Feedertyp 1 - 8mm Feeder \
\ Feeder-Typ -- Spurart \ 80, Track type for 8mm surf tape feeder none
\ R: Feeder Nadelhub [1/10mm] \ 0, Reserved none
\ Wartezeit Ausstossernadel [0.01s] \ 20, Time for extending the feeder needle *3) time value
\ Folienabloesezeit [0.01s] \ 20, Wait time for removing the foil time value
\ Reserve \ 0> Reserved none
\ Feedertyp 2 - 12mm Feeder \
\ Feeder-Typ -- Spurart \ 81, Track type for 12mm surf tape feeder none
\ R: Feeder Nadelhub [1/10mm] \ 0, Reserved none
\ Wartezeit Ausstossernadel [0.01s] \ 30, Time for extending the feeder needle *3) time value
\ Folienabloesezeit [0.01s] \ 20, Wait time for removing the foil time value
\ Reserve \ 0| Reserved none
\ Feedertyp 3 – 16mm Feeder \
\ Feeder-Typ -- Spurart \ 82, Track type for 16mm surf tape feeder none
\ R: Feeder Nadelhub [1/10mm] \ 0, Reserved none
\ Wartezeit Ausstossernadel [0.01s] \ 40, Time for extending the feeder needle *3) time value
\ Folienabloesezeit [0.01s] \ 30, Wait time for removing the foil time value
\ Reserve \ 0| Reserved none
\ Feedertyp 4 - 24mm Feeder \
\ Feeder-Typ -- Spurart \ 83, Track type for 24mm surf tape feeder none
\ R: Feeder Nadelhub [1/10mm] \ 0, Reserved none
\ Wartezeit Ausstossernadel [0.01s] \ 50, Time for extending the feeder needle *3) time value
\ Folienabloesezeit [0.01s] \ 50, Wait time for removing the foil time value
\ Reserve \ 0| Reserved none
\ *** Gehaeuseformarray IC-Kopf *** \ List of PFs for pick-up from surf tape feeder with IC head
\ Gehaeuseform 1 \
\ Gehaeuseform-Nr. \ 2001, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 100, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0> Reserved none
etc. up to:
\ Gehaeuseform 20 \
\ Gehaeuseform-Nr. \ 0, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 50, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0| Reserved none
\ *** Gehaeuseformarray SP-Kopf *** \ List of PFs for pick-up from surf tape feeder with SP head
\ Gehaeuseform 1 \
\ Gehaeuseform-Nr. \ 2011, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 50, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0> Reserved none
10 Component Handling SIPLACE 80 S20/F4/F4-6/F5 User’s Manual
10.10 Surf tape feeder module (applies to 80F5 with DCA option only) Edition 03/98 from Software Version SR.404.xx
10 - 38
etc. up to:
\ Gehaeuseform 100 \
\ Gehaeuseform-Nr. \ 714, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 100, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0 Reserved none
Save the modified DCA.MA file.
Close the editor.
PLEASE NOTE:
You must restart the station computer before the changes to the DCA.MA file can take effect.
Shut down the station computer.
PLEASE NOTE:
Do not just switch off the computer. Use ’Exit’ from the ’Start’ menu to shut down WINDOWS. If you do not
do this, you will lose your data because it was not saved. It is also possible to damage your file system.
Reboot the station computer.
The new machine data will be loaded when you restart the program.
Notes on editing the DCA.MA file:
*1) Exclusive OR function:
Only one function may be used at any given time. If ‘Wait time during placement’ is active, the surf tape
feeder function must be deactivated.
PLEASE NOTE
The ’Wait time during placement’ function is a special option and must be switched off during placement
from surf tape feeders.
*2) The power stage for picking up components from the surf tape feeder module can be converted from the
standard value 0 (= power stage 1) to the values set in the KRAFT.MA file under power stage 14.
Power record 14 in the axis record for the Z axis concerned (SP head, IC head) is reserved for this set-
ting.
*3) The time required to extend the pusher needle depends on the travel of the selected pusher needle.
Check chapter 16 of the feeder module operating instructions for setting the pusher needle travel.
SIPLACE 80 S20/F4/F4-6/F5 User’s Manual 10 Component Handling
Edition 03/98 from Software Version SR.404.xx 10.10 Surf tape feeder module (applies to 80F5 with DCA option only)
10 - 39
10.10.4 Settings when starting for the first time
1. Set the switch options for the surf tape feeder to “1”.
2. You can select a pick-up force other than the standard force (see *2, Page 10 - 38).
3. Modify the ‘Wait time for pusher needle‘ and ‘Foil removal time‘ feeder data to suit the feeder type used.
4. Enter the package form numbers, specifying the wait time during placement in the package form arrays
(SP head and/or IC head) for placement from surf tape feeders.
5. You can enter a placement force other than the standard force.
10.10.5 Maintaining the DCA.MA file
1. Maintain the following feeder data for all the feeder types used:
’Wait time for pusher needle‘
’Foil removal time‘
2. Maintain the package form numbers, specifying the wait time during placement in the package form
arrays (SP head and/or IC head) for placement from surf tape feeders.
r