SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options Edition 03/98 from Software Version SR.404.xx 11.7 Dispenser Flux A pplication Unit for SIPLACE 80F4/F4-6/F5 11 - 45 To edit a c omponent, you wi ll n…

100%1 / 744
11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F4-6/F5 Edition 03/98 from Software Version SR.404.xx
11 - 44
Volume:
- The quantity of flux in [µl] which is to be applied for the component in question.
- You may specify a flux volume between 1 µl and 100 µl.
- You can try out the following values as guidelines:
Component 6 mm x 6 mm => 8 µl flux
Component 10 mm x 10 mm =>10-15 µl flux
Dwell time:
- The period of time for which the component should be held in the flux during placement.
- You can specify a value between 0 and 500/100 seconds. This corresponds, of course, to 0 to 5 sec-
onds.
Comment:
- You can enter a comment for each component.
Confirm what you have entered by pressing OK.
Save the edited package form list by pressing Accept.
PLEASE NOTE
Up to 25 package forms can be entered on the station computer.
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options
Edition 03/98 from Software Version SR.404.xx 11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F4-6/F5
11 - 45
To edit a component, you will need to select the line in question (see Fig. 11.7.8 )
Click on the Edit button to edit an existing component.
Fig. 11.7.8 Fluxing: editing the package form list
- Key to Fig. 11.7.8
1 Select line 2 Edit button
3 Input fields
Edit the data as described for Add.
Confirm what you have entered by pressing OK.
Save the edited package form list by pressing the Accept button.
3 1 2
11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
11.7 Dispenser Flux Application Unit for SIPLACE 80F4/F4-6/F5 Edition 03/98 from Software Version SR.404.xx
11 - 46
11.7.6.3 Editing Flux Parameters
Select the Parameters menu if you wish to specify data for the fluxing procedure.
Fig. 11.7.9 Editing flux parameters
PCB conveyor wait time:
- The wait time (or dwell time) is the time period the board remains in the station until further placement
occurs. This ensures that the flux dries properly and the components do not ‚float away‘.
- This time period is measured from the flip-chip component last inserted.
- You can specify a time between 0 and 40 seconds.
PLEASE NOTE
The line utilization will be affected if you set this waiting time.