5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5.6 Test Component Edition 03/98 from Software Version SR.404.xx 5 - 120 Line engine er If you ar e insertin g flip-chi ps with hi gh reprodu cibilit y, i.e. if …

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 119
5.6.4.21 ’Ball’ measuring mode
Click on the ’Settings’ button in ’Ball’ measuring mode to call up the ’’Ball measuring mode“ menu.
Fig. 5.6.33 ’Measuring mode’ option, ’’Ball measuring mode“ menu
This menu can be used to
select the measuring methods listed under ’Measurement’ and
evaluate the position and presence of balls and carry out a quality analysis.
Measurement
You can choose between the following measuring methods:
the profile method for fast analysis or
the filter method for a more robust measuring method, although this will take longer.
The ’fast’ measuring method is generally sufficient. However, we recommend the ’robust’ measuring method if
the quality is insufficient, for example if the quality factor is less than 50.
Analysis
This is used to analyze the position of the balls and to determine whether they are present. It can also be used
to determine the quality of the measurement. The quality of the measurement should generally be better than
50.
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.6 Test Component Edition 03/98 from Software Version SR.404.xx
5 - 120 Line engineer
If you are inserting flip-chips with high reproducibility, i.e. if there is very little difference between the optical
parameters of the flip-chips, we recommend the following settings to guarantee fast insertion:
Switch off the determination of position / presence for components with large balls and spacing. The posi-
tion of the components has already been adequately determined using the grid measurement of 3 balls per
corner, and the ball presence analysis is unnecessary.
Do not activate determination of the quality of the measurement unless you want to detect handling or pro-
duction errors.
Determination of the position is always necessary if the individual ball positions differ greatly from the grid
structure, i.e. if the individual ball positions are fairly scattered about the desired position.
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.7 Guidelines for Describing Package Forms
Line engineer 5 - 121
5.7 Guidelines for Describing Package Forms
5.7.1 Transfer of Package Form Data and the Package Form Interpreter
If a package form is transferred to the station without an .SST file, the package form interpreter will make cer-
tain settings to enable the package form to be measured in accordance with the package form description.
Fig. 5.7.1 Transfer of package form data without package form manipulation
In SIPLACE 80 S-20/F
4
/F
4
-6/F
5
automatic placement machines, the package form interpreter is located in the
machine controller. The communication module transfers the signals for controlling the lighting from the MC to the
cameras.
Tasks of the Package Form Interpreter
Automatic selection of suitable measuring modes
Automatic selection of the measuring parameters
Automatic differentiation between cubic/not cubic
Automatic setting of the lighting
The package form interpreter processes standard components and automatically identifies special compo-
nents. Under certain circumstances, other components have to be post-processed. If the package form set-
tings have to be manipulated, these changes will be stored in the .SST file and transferred back to the line
computer.
GF manipulator
LC
Package form library
Describe package form & components
Assign nozzles
Select cameras
Hard disk
.OGF
Package form interpreter
Automatic selection of meas. modes
Automatic lighting selection
SC
MVS