80S-2080F480F4-680F5 User’s Manual.pdf - 第291页
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5.5 Teach Fiducial Edition 03/98 from Software Version SR.404.xx 5 - 70 Line engine er

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.5 Teach Fiducial
Line engineer 5 - 69
5.5.6.4
PCB onto Center Conveyor
Option
Click on the PCB to center conveyor button and the following actions will be executed:
1. There is a board on the input conveyor.
– The conveyor belt starts and conveys the board as far as the stopper.
– The board will be clamped.
2. There is no board on the input conveyor.
– The message appears: ’No PCB on the input conveyor’.
– Insert a board.
– Click on the PCB to center conveyor button.
– The conveyor belt starts and conveys the board as far as the stopper.
– The board will be clamped.
NOTE
If there is already a board on the center conveyor, this function will be blocked. You will then see a mes-
sage informing you that there is already a board on the center conveyor.
NOTE
If a twin conveyor is installed you can use the buttons in the option box ’Conv. selection’ to select con-
veyor 1 or conveyor 2.
5.5.6.5
PCB to Output Conveyor
Option
This function will only be executed when there is a board on the center conveyor.
NOTE
When you quit the menu the board will be transported automatically onto the output conveyor.
NOTE
If a twin conveyor is installed you can use the buttons in the option box ’Conv. selection’ to select conveyor 1
or conveyor 2.
5 Vision Functions SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
5.5 Teach Fiducial Edition 03/98 from Software Version SR.404.xx
5 - 70 Line engineer

SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 5 Vision Functions
Edition 03/98 from Software Version SR.404.xx 5.6 Test Component
Line engineer 5 - 71
5.6
Test Component
5.6.1
Test Component
Flow Chart
The Test component flow chart shows in graphic form all menu options together with their sub-functions. The
menus are indicated by being bordered with an unbroken line, while the option boxes use a dash-dotted line
and the input boxes a center line.
To flow chart „Test component“ part 1
To flow chart „Test component“ part 2
To flow chart „Test component“ part 3
To flow chart „Test component“ part 4
5.6.2 Information on the
Test Component
Flow Chart
5.6.2.1 Menus
The Test component option includes the following menus:
– Select package form
– Test component
The Save component name option box will drop down every time you wish to quit the Test component
menu having previously generated or modified GF data. This gives you the choice of either saving or discard-
ing the GF data in question.
You can quit the individual menus by clicking on either the icons of another menu or on the Main view icon.
5.6.2.2 Input Boxes, Option Boxes
For data input, displaying values and initiating actions the system offers the following input boxes:
– Measure mode
– Adjust contrast sensitivity
– Select component type (80F
4
, 80F
4
-6 or 80F
5
machines only)
You can quit the input boxes by clicking on OK, Accept or Cancel.
– Click on OK or Accept to have the program save the data. The box will then close.
– Click on the Cancel button to discard the data, after which the input box will close.