2OM-1733 2-2-8 2.7 Composition of Placement Data The set parameters are used to place the components (IDs in the placement feeder location data) on the points with the specied coordinates in the designated direction. On…

2OM-1733
2-2-7
2.5 Composition of Placement Nozzle Data
The set parameters are used to place the nozzles onto the specied positions on
the head (Place Head/Noz No.).
Reference
Refer to "3.5 PL Head / Nozzle" for the details of each item according to the
reference Nos. (Ref. Nos.).
E01 Nozzle Place
Table 2B2-10
Items Ref. No.
Nozzle Place (E01-01)
Nozzle Stk 11 (E02)
Nozzle Stk 12 (E02)
Nozzle Stk 21 (E02)
Nozzle Stk 22 (E02)
2.6 Composition of Placement Feeder Location Data
The set parameters are used to determine which feeder slot Nos. (Fdr No.) various
types of components should be allocated to.
Component IDs (types of components to be allocated) must be specied for each
individual feeder bases.
Reference
Refer to "3.6 CMPNT PL" for the details of each item according to the reference
Nos. (Ref. Nos.).
F01 CMPNT PL
Table 2B2-11
Items Ref. No.
Fdr No. (F01_01)
Component ID (F01_02)
C (Control Command) (F01_03)
Comment (F01_04)
Feeder Fixed (F01_05)
Feeder Alternate (F01_06)
Fdr No. (F01_07)
Component Library Comment (F01_08)
Dir [deg], Carrier Data Type, Width [mm] (F01_09)
Fd. Pitch [mm] (F01_10)
Used Parts (F01_11)
Nozzle Type (F01_12)
1212-003
2.5 Composition of Placement Nozzle Data

2OM-1733
2-2-8
2.7 Composition of Placement Data
The set parameters are used to place the components (IDs in the placement feeder
location data) on the points with the specied coordinates in the designated
direction.
One step is allocated for each component to be placed.
Reference
Refer to "3.7 Placement Data" for the details of each item.
G01 Placement
Table 2B2-12
Items Ref. No.
Un (G01-01)
Offset Data (G02)
Offset (G02)
Unit Control (G02_01)
Offset
X [mm], Y [mm], Z [ ° ], H [mm]
(G02_02)
Unit PCB Fiducial (G02_03)
Recog Coord
X1, Y1, X2, Y2
(G02_04)
Fiducial Mark
FM1, FM2
(G02_05)
D-Data (G03)
P-Data (G03)
PNo. (G03_01)
X [mm], Y[mm] (G03_02)
Z [ ° ] (G03_03)
H [mm] (G03_04)
Component ID (G03_05)
Fdr. No. (G03_06)
Symbol (G03_07)
C (G03_08)
Comment (G03_09)
ADJ X,Y (G03_10)
O-Data (G04)
Ono. (G04_01)
X [mm], Y[mm] (G04_02)
Z [ ° ] (G04_03)
H [mm] (G04_04)
C (G04_05)
Comment (G04_06)
B-X, B-Y (G04_07)
1212-003
2.7 Composition of Placement Data

2OM-1733
2-3-1
3. Explanation of Pattern Program
In this instruction manual, the placement coordinate reference is based on "Front
Right".
3.1 Common SET
Note
This data is used in the dual transfer operation (option).
1204-001
3. Explanation of Pattern Program