2OM-1733-005w_F8.pdf - 第314页

2OM-1733 6-6-6 6.3 "MNL XFER" Window This "MNL XFER" window enables the operator to transfer a PCB manually. [3] [2] [3] [3] [2] [3] [4] [1] Fig. 2F6-4 [1] Conveyor Image Display Section Each block of…

100%1 / 358
2OM-1733
6-6-5
6.2 "Line" Tab Sheet
This tab sheet enables the operator to transfer a PCB between two or more
machines.
[1]
Fig. 2F6-3
[1] Conveyor Image Display Section
Each block of the conveyor of which an image is displayed, functions as a
button.
When the conveyor block button is pressed and within 10 seconds, the
[START] button on the operation panel is pressed, the PCB is transferred to
the position.
Note
(a) This button is displayed when two or more machines are installed in the
line.
(b) Up to 16 conveyor blocks are displayed.
1212-002
6.2 "Line" Tab Sheet
2OM-1733
6-6-6
6.3 "MNL XFER" Window
This "MNL XFER" window enables the operator to transfer a PCB manually.
[3] [2] [3] [3] [2] [3]
[4]
[1]
Fig. 2F6-4
[1] Conveyor Image Display Section
Each block of the conveyor, of which an image is displayed, functions as a
button.
[2] PCB LOCATE L and PCB LOCATE R
Using these buttons, PCB positioning is performed.
When the [Exec.] button is pressed and within 10 seconds, the [START]
button is pressed on the operation panel, the PCB positioning operation is
performed.
When the [Rlse.] button is pressed and within 10 seconds, the [START]
button is pressed on the operation panel, the PCB positioning operation is
performed.
[3] [Stpr L] and [Stpr R]
Using these selection buttons, the stopper positioning is performed.
When the [MOVE UP] button is pressed and within 10 seconds, the [START]
button is pressed on the operation panel, the stopper is moved up.
When the [MOVE DOWN] button is pressed and within 10 seconds, the
[START] button in pressed on the operation panel, the stopper is moved
down.
1403-004
6.3 "MNL XFER" Window
2OM-1733
6-6-7
[4] XFER Start
Using this function, the PCB transfer operation is performed.
Select the block for the conveyor to be moved in the [1] Conveyor Image
Display Section (two or more blocks can be selected).
After selecting the block, when the transfer button for the selected direction
for the PCB transfer, is pressed and within 10 seconds, the [START] button
on the operation panel is pressed, the conveyor in the selected block is
moved as long as the button is pressed.
When the PCB reaches the sensor position at the end of the transfer direction
range, the conveyor is stopped.
1403-004
6.3 "MNL XFER" Window