2OM-1733 1-4-2 4.1 "Run Mode" T ab Sheet [3] [1] [2] Fig. 2A4-2 [1] "Run Mode" Selection Buttons Press either one of the following buttons to select the desired run mode. [Place] Button : Select this …

100%1 / 358
2OM-1733
1-4-1
4. "OPERATION" Window
The constraints based on the designation of any of the various operation modes in
the automatic operation and operation method in the test operation, are set in this
window.
[1]
Fig. 2A4-1
[1] Tabs and Tab Sheets
The "OPERATION" window is provided with the following three tabs.
When each tab is pressed, the corresponding tab sheet appears inside the
window.
Table 2A4-1
Tabs Description
Run Mode
The corresponding tab sheet enables the operator to change the
operation mode or stop the production.
Opr. Mode
The corresponding window enables the operator to select an operation
mode such as Over Tact-Time Reduction.
Test Mode
The corresponding window enables the operator to set test modes.
Graphic
Development
1212-002
4. "OPERATION" Window
2OM-1733
1-4-2
4.1 "Run Mode" Tab Sheet
[3]
[1]
[2]
Fig. 2A4-2
[1] "Run Mode" Selection Buttons
Press either one of the following buttons to select the desired run mode.
[Place] Button
: Select this button to set the machine in the "PLACE
(Automatic Operation)" mode.
[Pass] Button
: Select this button to set the machine in the "PASS" mode.
In the case that the pass operation has been setup, "PASS" is displayed in the
"Status Indicator" on the upper area of the "Product" window.
Status Indicator
Fig. 2A4-3
[2] "Start Mode" Selection Buttons
Using the following buttons, the start mode is setup.
[Auto] Button
: Select this button to start up the machine
automatically.
[1 Comp Placement] Button
: Select this button to stop the machine after
the designated single component has been
placed.
Graphic
Development
1212-002
4.1 "Run Mode" Tab Sheet
2OM-1733
1-4-3
[3] Cancel Run
When the Cancel Run button is pressed, the "Pause" condition is cancelled
and the machine is turned to the "STOP" mode.
Note
When the machine is set in the "PAUSE" mode by pressing the [STOP]
button on the operation panel during the automatic operation, etc., the
Cancel Run button becomes available.
1212-002
4.1 "Run Mode" Tab Sheet