2OM-1733
1-4-14
4.2.3 Control
When the [Control] button is pressed on the "Opr. Mode" tab sheet, the following
window appears.
[1]
[2]
[3]
[4]
Fig. 2A4-11
[1] Recovery Mode
For the Recovery Mode, select "Immediately Stop (Priority of Reload)",
"Recovery Mode" or "All Recovery Mode".
Table 2A4-2
Recovery Mode
When the component shortage has been detected: Treatment when a pick-up
error has been detected
Treatment "Alternate" has been setup.
Stop Auto Run
When the component shortage is
detected, the machine is stopped
immediately.
When the component shortage is
detected, the alternative operation
is started up.
When the component shortage is
detected, the machine is stopped
immediately.
Aft Other Plcmnt
When the component shortage
is detected, the machine is not
stopped immediately. In turn,
the machine information is
issued, prompting the operator to
replenish the components. Then,
after placing the components
other than the missing ones,
the machine is stopped without
discharging the PCB.
When the component shortage is
detected, the alternative operation
is not started up immediately, but
after the PP nal step.
When the pick-up error is
detected, the components for the
next cycle are used to recover the
operation.
Batch Recovery
When the component shortage is
detected, the alternative operation
is started up.
When the component shortage is
detected, the alternative operation
is started up.
After the pick-up error is
detected, the operation is
continues using the spare nozzles
set up for the following cycles.
When there is no spare nozzle,
recovery operation is performed
lastly using the components for
the following cycles for recovery.
1212-002
4.2 "Opr.Mode" Tab Sheet

2OM-1733
1-4-15
[2] Plcmnt Auto Adjust
This function is available only when the double beam recognition has been
set in the pattern program.
Disable
The double beam recognition is always performed.
Enable
When pressed, the double beam recognition is performed with the interval
based on the data in the machine. Normally, single beam recognition is
performed using the recognition results using the double beam as the
correction values. The cycle time can be reduced with this function.
[3] High Accuracy Mode
It is set when ne components such as 0402 component, are to be placed.
Disable
When selected, the high-accuracy mode is not used.
Enavle
When selected, the high-accuracy mode is used. The placement speed is
reduced to 40% in X-axis and to 20% in Y-axis.
1204-001
4.2 "Opr.Mode" Tab Sheet

2OM-1733
1-4-16
[4] "Component Remain Mode" Group Box
The component remainder management function (mode) is used to count the
number of components picked from the feeder, manage it, and provide the
related information.
Func Set
Disable
Select this button not to use the component remainder management mode.
Enable
Select this button to use the component remainder management mode.
When the [Enable] button is selected, an alarm will be issued, indicating
that the machine will soon be short or empty of components.
Zero Stop Func
Disable
When this button is pressed, the feeder does not stop working after the
number of remaining components has reached "0" (zero).
Splicing
When this button is pressed and the number of remaining components has
reached "0" (zero), the deciency is regarded as a component shortage
error and the feeder stops working.
In this case, it is required to reload the components afterward.
ALL
When this button is pressed and the number of remaining components
has reached "0" (zero) for all feeders, the deciency is regarded as a
component shortage error and the feeder (the machine) stops working.
1204-001