OM-1068-001.pdf - 第117页
8. Stop Operation 8.1 General Stop Procedure • The tray feeders are not provided with any [STOP] button. The [ST OP] button of the main machine is commonly used for the feeders. • Press the [STOP] button of the main mach…

(9) Press the [SUPPLY] key at the display (Fig. 1.40).
The display (Fig. 1.42) appears on the screen.
Fig. 1.42
(10) Confirm that components are supplied completely and press the [YES]
key to declare the completion of component replenishment.
The color of all stage and block No. keys for which components are
supplied changes from violet to green.
[YES] Key: When this key is pressed, the order of component picks is
changed to the matrix initial setting (1, 1) for all the stages
and blocks selected for component supply.
[NO] Key: When this key is pressed, the “COMPONENT REPLEN-
ISHMENT” display (Fig. 1.40) appears on the screen.
The color display maintains the state before the [SUPPLY]
key is pressed.
(11) Press the [U READY] or the [L READY] button. The door is locked.
(12) Re-start the operation.
• When the machine is in the automatic operation mode, the operation
starts automatically.
• When the machine is in the “PAUSE” mode, press the [START] button
of the main machine to re-start the operation.
Ref.: (a) When several pallets are short of components, follow Step (7)
every time components are supplied or another step (collective
operation) after all components are supplied.
(b) It is also possible to replenish the tray in the middle of processing
with components or replace it with another one.
In this case, it is required to update the tray matrix.
Refer to “4. Matrix Change Operations of Section 3 in Chapter 1”
in this booklet and “7. Tray Pick-Up Matrix (Option) of Section 3
in Volume 1” in the main machine instruction manual for details.
7. Component Replenishment during Automatic Operation
9911-001 Chapter 1 2-33 Tg0252-PM-SO

8. Stop Operation
8.1 General Stop Procedure
• The tray feeders are not provided with any [STOP] button.
The [STOP] button of the main machine is commonly used for the feeders.
• Press the [STOP] button of the main machine.
The LED of the [START] button extinguishes. After placing all components
on the P.C.B. in the middle of production process, each individual devices
return to their stationary position and the machine stops running.
• The green tower light of the main machine extinguishes.
8.2 Automatic Stop Procedure
• Stop the input machine. The machine processes all P.C.B.’s on the system
line, discharges them, and stops running automatically.
Notes: (a) It is assumed that “ENABLE” is set in the “AUTO STOP
MODE” data box at the “P.C.B. TRANSFER MODE SET-UP”
display. (Hierarchical Sequence: “DEVICE DATA” Display →
“P.C.B. TRANSFER MODE SET-UP” Display)
(b) When a machine of another brand is connected to the system
line, this function may not work.
8.3 Emergency Stop Procedure
• The tray feeders are not provided with any [EMERGENCY STOP] button.
The [EMERGENCY STOP] buttons of the main machine are commonly
used for the feeders.
• To stop the machine instantaneously in an emergency, press one of the
[EMERGENCY STOP] buttons of the main machine.
Power to the loads is shut off and the machine stops running instantaneously.
Refer to “6.7.2 Reset and Start Procedure from Emergency Stop of Section
2 in Volume 1” in the main machine instruction manual for the procedure to
reset the machine to the normal condition from an emergency stop.
8. Stop Operation
0010-002 Chapter 1 2-34 Tg0252-PM-SO

9. Interruption of Automatic Operation
• How to Interrupt the Automatic Operation of the Main Machine
(1) Immediately after it is found that a wrong pattern program (due to wrong
selection of pattern program data or wrong program change operation) is
used as a current one after the machine starts automatic operation, press
the [PAUSE] button of the main machine to stop the automatic operation
temporarily.
(2) After the machine has stopped, press the [SYS CLR] button to interrupt
the operation in progress and reset the machine to the normal condition.
The automatic operation is interrupted.
• Refer to “6.6.2 Function of [SYS CLR] Button of Section 2 in Volume 1” in
the main machine instruction manual for the detailed information on the
function of the [SYS CLR] button.
9. Interruption of Automatic Operation
0010-002 Chapter 1 2-35 Tg0252-PM-SO