OM-1068-001.pdf - 第163页

0005-002 Chapter 3 2-2 Tg0252-PM-SO 1. ERROR Display When a device in operation is interrupted or stopped in an error condition (error condition detected as impossible to continue the operation), an “ER- ROR” display (Fi…

100%1 / 273
0010-002 Chapter 3 2-1
Tg0252-PM-SO
Troubleshooting based on Error Indication
Section 2
0005-002 Chapter 3 2-2 Tg0252-PM-SO
1. ERROR Display
When a device in operation is interrupted or stopped in an error condition
(error condition detected as impossible to continue the operation), an “ER-
ROR” display (Fig. 3.2) appears on the screen.
The same display also appears on the operation monitor of the main machine.
Refer to “Error Messages of Section 2 in Volume 3” in the main machine
instruction manual for details.
When an error occurs during automatic operation, the tower light of the
main machine illuminates (standard setting) and an “ERROR” display ap-
pears on the screen. The “ERROR” display also appears when an error oc-
curs while a device is running (while the LEDs of the [START], [MOVE],
[ZERO], and [READY] buttons are ON).
Fig. 3.1
Fig. 3.2
“Occurrence of Error”
1. ERROR Display
E
D
C
B
A
0005-002 Chapter 3 2-3 Tg0252-PM-SO
A : Error Message
B : Details of Error Message
C : Guidance to the Cause and Remedy of Error
(Some errors may not be displayed.)
Refer to “4. Troubleshooting after Error Messages of Section 2 in Chapter 3”
for details (error messages, details of error messages, cause, remedy, etc.).
D : This key is used to stop buzzer sound.
E : Buzzer sound stops and the display before an error has occurred resumes.
2. Remedial Procedure after Error Display
Operation Procedure
(1) Press the [BUZZER STOP] key.
(See Fig. 3.2.)
The buzzer stops sounding.
(2) Check the contents of the error message and the remedial procedure
(GUIDANCE TO CAUSE AND REMEDY) displayed on the operation
monitor.
Ref.: “4. Troubleshooting after Error Messages of Section 2 in Chapter
3” for details.
(3) Remove the cause of the error.
Different countermeasures and remedial procedures must be taken,
depending on the type of an error.
Remedial Procedure when power must be re-supplied or the system
clear operation must be performed
(1) Refer to “6.7.2 Reset and Start Procedure from Emergency Stop
of Section 2 in Volume 1” in the main machine instruction
manual for details.
Remedial Procedure when the zeroing operation must be performed
(1) Press the [RTN] key.
(2) Perform the zeroing operation.
Refer to “2. Zeroing Operation of Section 4 in Chapter 1” for
details.
Remedial Procedure when the cause of an error is removed without
performing the zeroing or the system clear operation or just for
message confirmation
(1) Press the [RTN] key.
(2) The display before the “ERROR” display resumes.
(3) Refer to the instructions (GUIDANCE TO CAUSE AND
REMEDY) and remove the cause.
2. Remedial Procedure after Error Display