01 12-001 C h ap t er 3 2-25 Tg0252-PM-SO 4. Troubleshooting after Error Message Error Code Display A Display B (Reset Procedure in the case of Causes 1 and 2) Reset Procedure ( 1 ) Press the [RESET] button to cancel the…

0112-001 Chapter 3 2-24 Tg0252-PM-SO
4. Troubleshooting after Error Message
12 05 TV2-AXIS INTERLOCK Reserved
12 05 02 TV2-AXIS INTERLOCK TRAVERSE 1 PATH LINE [BPH276] DETECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
PCB
Beam A Side
Beam B Side
C
(Cause 1) Is there any foreign substance on the tray?
Check the tall component on the pallet.
(Cause 2) Is the component not properly in the tray?
A component which was not picked up might be
sticking out from the tray.
(Cause 3) Is the height of the tray close to the specified
maximum limit?
(NEXT PAGE)

0112-001 Chapter 3 2-25 Tg0252-PM-SO
4. Troubleshooting after Error Message
Error Code Display A Display B
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error indication.
(2) Press the [READY] key on the operation panel on the side of the beam A to turn off the LED
for the [READY] key.
(3) Press the [EMERGENCY STOP] button
to turn off the load power, then open
the supply cover on the side of the
beam A.
Take the greatest care for safety.
(4) Remove any foreign substance,
such as a projecting component,
which caused the error.
(5) Close the supply cover and press the [POWER]
button to turn on the load power.
(6) Press the [READY] button on the side of the beam A to turn on the LED for the [READY]
button.
(7) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(Reset Procedure in the case of Cause 3)
Reset Procedure
(1) Contact our service personnel.

0112-001 Chapter 3 2-26 Tg0252-PM-SO
4. Troubleshooting after Error Message
12 05 03 TV2-AXIS INTERLOCK CHUTE CARRIAGE CHECK #1 (UPPER) [BPH266]
DETECTED.
12 05 04 TV2-AXIS INTERLOCK CHUTE CARRIAGE CHECK #2 (UPPER) [BPH267]
DETECTED.
Error Code Display A Display B
12 05 05 TV2-AXIS INTERLOCK CHUTE CARRIAGE CHECK #3 (UPPER) [BPH268]
DETECTED.
12 05 06 TV2-AXIS INTERLOCK CHUTE CARRIAGE CHECK #4 (UPPER) [BPH269]
DETECTED.
(Cause 1) Is there any foreign substance on the chute?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] key to cancel the error indication.
(3) Press the [READY] button on the operation panel on the side of the beam A to turn off the
LED for the [READY] button.
(4) Press the [EMERGENCY STOP] button to turn off the load power, then open the supply cover
on the side of the beam A. Take the greatest care for safety.
(5) Remove any foreign substance, such as a projected component, which caused the error.
(6) Close the supply cover and press the [POWER] button to turn on the load power.
(7) Press the [READY] button on the side of the beam A to turn on the LED for the [READY]
button.
(8) Press the [ZERO] button to return all axes to their original positions. Continue production
according to the “WARM Start Operation Procedure”.