OM-1068-001.pdf - 第118页
9. Interruption of Automatic Operation • How to Interrupt the Automatic Operation of the Main Machine (1) Immediately after it is found that a wrong pattern program (due to wrong selection of pattern program data or wron…

8. Stop Operation
8.1 General Stop Procedure
• The tray feeders are not provided with any [STOP] button.
The [STOP] button of the main machine is commonly used for the feeders.
• Press the [STOP] button of the main machine.
The LED of the [START] button extinguishes. After placing all components
on the P.C.B. in the middle of production process, each individual devices
return to their stationary position and the machine stops running.
• The green tower light of the main machine extinguishes.
8.2 Automatic Stop Procedure
• Stop the input machine. The machine processes all P.C.B.’s on the system
line, discharges them, and stops running automatically.
Notes: (a) It is assumed that “ENABLE” is set in the “AUTO STOP
MODE” data box at the “P.C.B. TRANSFER MODE SET-UP”
display. (Hierarchical Sequence: “DEVICE DATA” Display →
“P.C.B. TRANSFER MODE SET-UP” Display)
(b) When a machine of another brand is connected to the system
line, this function may not work.
8.3 Emergency Stop Procedure
• The tray feeders are not provided with any [EMERGENCY STOP] button.
The [EMERGENCY STOP] buttons of the main machine are commonly
used for the feeders.
• To stop the machine instantaneously in an emergency, press one of the
[EMERGENCY STOP] buttons of the main machine.
Power to the loads is shut off and the machine stops running instantaneously.
Refer to “6.7.2 Reset and Start Procedure from Emergency Stop of Section
2 in Volume 1” in the main machine instruction manual for the procedure to
reset the machine to the normal condition from an emergency stop.
8. Stop Operation
0010-002 Chapter 1 2-34 Tg0252-PM-SO

9. Interruption of Automatic Operation
• How to Interrupt the Automatic Operation of the Main Machine
(1) Immediately after it is found that a wrong pattern program (due to wrong
selection of pattern program data or wrong program change operation) is
used as a current one after the machine starts automatic operation, press
the [PAUSE] button of the main machine to stop the automatic operation
temporarily.
(2) After the machine has stopped, press the [SYS CLR] button to interrupt
the operation in progress and reset the machine to the normal condition.
The automatic operation is interrupted.
• Refer to “6.6.2 Function of [SYS CLR] Button of Section 2 in Volume 1” in
the main machine instruction manual for the detailed information on the
function of the [SYS CLR] button.
9. Interruption of Automatic Operation
0010-002 Chapter 1 2-35 Tg0252-PM-SO

10. Shut-Down Operation (End of Production)
Press the [POWER OFF] button on the operation panel.
Turn off the power breaker (
{) located on the front side of the machine to
shut off the power completely.
10. Shut-Down Operation (End of Production)
0010-002 Chapter 1 2-36 Tg0252-PM-SO