9. Interruption of Automatic Operation • How to Interrupt the Automatic Operation of the Main Machine (1) Immediately after it is found that a wrong pattern program (due to wrong selection of pattern program data or wron…

100%1 / 273
8. Stop Operation
8.1 General Stop Procedure
The tray feeders are not provided with any [STOP] button.
The [STOP] button of the main machine is commonly used for the feeders.
Press the [STOP] button of the main machine.
The LED of the [START] button extinguishes. After placing all components
on the P.C.B. in the middle of production process, each individual devices
return to their stationary position and the machine stops running.
The green tower light of the main machine extinguishes.
8.2 Automatic Stop Procedure
Stop the input machine. The machine processes all P.C.B.’s on the system
line, discharges them, and stops running automatically.
Notes: (a) It is assumed that “ENABLE” is set in the “AUTO STOP
MODE” data box at the “P.C.B. TRANSFER MODE SET-UP”
display. (Hierarchical Sequence: “DEVICE DATA” Display
“P.C.B. TRANSFER MODE SET-UP” Display)
(b) When a machine of another brand is connected to the system
line, this function may not work.
8.3 Emergency Stop Procedure
The tray feeders are not provided with any [EMERGENCY STOP] button.
The [EMERGENCY STOP] buttons of the main machine are commonly
used for the feeders.
To stop the machine instantaneously in an emergency, press one of the
[EMERGENCY STOP] buttons of the main machine.
Power to the loads is shut off and the machine stops running instantaneously.
Refer to “6.7.2 Reset and Start Procedure from Emergency Stop of Section
2 in Volume 1” in the main machine instruction manual for the procedure to
reset the machine to the normal condition from an emergency stop.
8. Stop Operation
0010-002 Chapter 1 2-34 Tg0252-PM-SO
9. Interruption of Automatic Operation
How to Interrupt the Automatic Operation of the Main Machine
(1) Immediately after it is found that a wrong pattern program (due to wrong
selection of pattern program data or wrong program change operation) is
used as a current one after the machine starts automatic operation, press
the [PAUSE] button of the main machine to stop the automatic operation
temporarily.
(2) After the machine has stopped, press the [SYS CLR] button to interrupt
the operation in progress and reset the machine to the normal condition.
The automatic operation is interrupted.
Refer to “6.6.2 Function of [SYS CLR] Button of Section 2 in Volume 1” in
the main machine instruction manual for the detailed information on the
function of the [SYS CLR] button.
9. Interruption of Automatic Operation
0010-002 Chapter 1 2-35 Tg0252-PM-SO
10. Shut-Down Operation (End of Production)
Press the [POWER OFF] button on the operation panel.
Turn off the power breaker (
{) located on the front side of the machine to
shut off the power completely.
10. Shut-Down Operation (End of Production)