01 12-001 C h ap t er 3 2-21 Tg0252-PM-SO 4. Troubleshooting after Error Message 12 01 07 TV2-AXIS ORIGIN TRA VERSE #2 MIDDLE ORIGIN [BPH262] NOT DE- TECTED. 12 01 08 TV2-AXIS ORIGIN CHUTE P ALLET CHECK #4 [BPH269, 273] …

0112-001 Chapter 3 2-20 Tg0252-PM-SO
4. Troubleshooting after Error Message
12 01 04 TV2-AXIS ORIGIN EXCITATION-MONITOR SIGNAL FROM STEPPING
MOTOR DRIVER WAS NOT DETECTED.
12 01 05 TV2-AXIS ORIGIN TRAVERSE #2 ORIGIN [BPH255] NOT DETECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
12 01 06 TV2-AXIS ORIGIN PALLET NOT STORED.
(Cause) Has the pallet to be housed been removed?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error indication.
(3) Press the [READY] button on the operation panel on the beam A side to turn off the LED for
the [READY] button.
(4) Press the [EMERGENCY STOP] button to shut down the load power and open the supply
cover on the beam A side. Take the greatest care about safety.
(5) Return the pallet which caused the error to its correct position.
(6) Close the supply cover and press the [POWER] button to turn on the load power.
(7) Press the [READY] button on the side of the beam A to turn on the LED for the [READY]
button.
(8) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.

0112-001 Chapter 3 2-21 Tg0252-PM-SO
4. Troubleshooting after Error Message
12 01 07 TV2-AXIS ORIGIN TRAVERSE #2 MIDDLE ORIGIN [BPH262] NOT DE-
TECTED.
12 01 08 TV2-AXIS ORIGIN CHUTE PALLET CHECK #4 [BPH269, 273] SENSORS
MAY BE DEFECTIVE.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
12 01 09 TV2-AXIS ORIGIN PALLET JERKED OUT OF MAGAZINE
DETECTED.;BPH586
(Cause 1) Is the pallet not properly in the magazine?
(Cause 2) There might be a non-conformity in the pallet projection detection sensor [BPH586].
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [U Ready] or [L Ready] key to open the multi-tray feeder door.
(4) Open the magazine door and set the projecting pallet to its correct position.
(5) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(Reset Procedure in the case of Cause 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.

0112-001 Chapter 3 2-22 Tg0252-PM-SO
4. Troubleshooting after Error Message
12 01 0A TV2-AXIS ORIGIN TRAVERSE AXIS (+) LIMIT [BPH256] SENSOR MAY BE
DEFECTIVE.
12 01 0B TV2-AXIS ORIGIN TRAVERSE 2 LEVER A ORIGIN [BPH264] NOT DE-
TECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
12 01 0C TV2-AXIS ORIGIN TRAVERSE 2 LEVER B ORIGIN [BPH265] NOT DE-
TECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
12 01 0D TV2-AXIS ORIGIN TRAVERSE 2 CLAMP AREA CHECK A [BPH264] NOT
DETECTED.
12 01 0E TV2-AXIS ORIGIN TRAVERSE 2 CLAMP AREA CHECK B [BPH254] NOT
DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.