OM-1068-001.pdf - 第219页

991 1-001 Chapter 3 3-4 Tg0252-PM-SO 3. List of Check Messages 3. List of Check Messages Item (Field * A ) Description (Field * B ) Cause and Remedy (*C) TURN OFF THE CIRCUIT BREAKER OF THE T RAVERSE AXIS CHECK THE CIRCU…

100%1 / 273
9911-001 Chapter 3 3-3 Tg0252-PM-SO
2. Reset Procedure after Check Message
Operation Procedure
(1) Press the [BUZZER STOP] key. (See Fig. 3.4.)
The buzzer stops sounding.
(2) Check the contents of the check message and the remedial procedure
(GUIDANCE TO CAUSE AND REMEDY) displayed on the operation
monitor.
(3) Remove the cause of the nonfulfillment of starting requirements.
(4) Press the [RTN] key. The original display resumes.
2. Reset Procedure after Check Message
9911-001 Chapter 3 3-4 Tg0252-PM-SO
3. List of Check Messages
3. List of Check Messages
Item (Field *A) Description (Field *B)
Cause and Remedy (*C)
TURN OFF THE CIRCUIT
BREAKER OF THE TRAVERSE
AXIS
CHECK THE CIRCUIT BREAKER
POWER IS NOT SUPPLIED TO
THE TRAY UNIT
CLOSE THE COVER AND THE PRESS
THE [READY]BUTTON
SAFETY
CIRCUIT
THE TRAVERSE AXIS IS
APPROACHING ABNORMALLY
TURN OFF THE POWER AND KEEP
EACH TRAVERSE AXIS AWAY FROM
EACH OTHER
THE POSITION OF THE
TRAVERSE AXIS IS INDEFINITE
ZERO THE TRAY UNIT
TRAVERSE
AXIS
THIS MAY INTERFERE WITH
HEAD U/D AXIS ON MAIN BODY
SIDE.
ZERO HAED U/D AXIS (BEAM A)ON
MAIN BODY SIDE.
THE ELEVATOR AXIS IS NOT AT
ITS ORIGIN
ZERO THE ELEVATOR AXISELEVATOR
AXIS
FEEDER CARRIAGE IS EJECTED
FROM MAGAZINE.
CHECK THE CONDITION OF FEEDER
CARRIAGE.
THE MAGAZINE FOR FEEDER
CARRIAGE IS NOT CONNECTED.
CONNECT THE SELECTED
MAGAZINE AND PERFORM THE
ZEROING OPERATION.
FEEDER CARRIAGE DIRECTION
[BPH595] WAS DETECTED.
CHECK THE DIRECTION OF FEEDER
CARRIAGE IN UPPER AND LOWER
MAGAZINES.
UPPER DOOR
ELECTROMAGNETIC LOCK
SWITCH [SQ501] WAS NOT
DETECTED.
CHECK THE UPPER DOOR
ELECTROMAGNETIC LOCK SWITCH.
[READY (UPR)] LED [HD503]
WAS NOT DETECTED.
PRESS THE [READY (UPR)] BUTTON
TO SET UPPER MAGAZINE IN
READY MODE.
MAGAZINE
LOWER DOOR
ELECTROMAGNETIC LOCK
SWITCH [SQ502] WAS NOT
DETECTED.
CHECK THE LOWER DOOR
ELECTROMAGNETIC LOCK SWITCH.
9911-001 Chapter 3 3-5 Tg0252-PM-SO
3. List of Check Messages
Item (Field *A) Description (Field *B)
Cause and Remedy (*C)
[READY (LWR)] LED [HD504]
WAS NOT DETECTED.
PRESS THE [READY (LWR)] BUTTON
TO SET LOWER MAGAZINE IN
READY MODE.
MAGAZINE
STORE THE DRAWN PALLET IN
THE MAGAZINE.
IT IS PROHIBITED TO UNLOCK THE
MAGAZINE WHILE THE PALLET IS
DRAWN OUT.
REMOVE TRAVERSE #1 PASS
LEVEL SENSOR SHADED. ;
BPH274
THERE IS A POSSIBILITY THAT THE
COMPONENT HAVING THE PICK-UP
ERROR IS PROTRUDING.
REMOVE TRAVERSE #2 PASS
LEVEL SENSOR SHADED. ;
BPH275
THERE IS A POSSIBILITY THAT THE
COMPONENT HAVING THE PICK-UP
ERROR IS PROTRUDING.
ZERO TRAY-L. THE EXCEPTIONAL ZEROING
SEQUENCE IS REQUIRED DUE TO
THE TRAY PASS LEVEL ERROR
HISTORY.
ZERO TRAY-R. THE EXCEPTIONAL ZEROING
SEQUENCE IS REQUIRED DUE TO
THE TRAY PASS LEVEL ERROR
HISTORY.
SET TRAY-L AND TRAY-R
OPERATION MODE TO "LINE
AND ZERO ALL DEVICES WITH
THE [ZERO] BUTTON.
THE EXCEPTIONAL ZEROING
SEQUENCE IS REQUIRED DUE TO
THE TRAY PASS LEVEL ERROR
HISTORY.
CLOSE COVER IN THE MIDDLE
OFF TARY-L.
THIS IS AN INTERLOCK CONDITION
FOR THE COLLISION AVOIDANCE OF
THE ELEVATOR SECTION.
ZEROING
CLOSE COVER IN THE MIDDLE
OFF TARY-R.
THIS IS AN INTERLOCK CONDITION
FOR THE COLLISION AVOIDANCE OF
THE ELEVATOR SECTION.