OM-1068-001.pdf - 第205页

01 12-001 C h ap t er 3 2-44 Tg0252-PM-SO 4. Troubleshooting after Error Message 14 0 1 07 EV2-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS. 14 0 1 08 EV2-AXIS ORIGIN Error Code Display A Display B 14 0 2 01 EV2-AXIS TIMI…

100%1 / 273
0112-001 Chapter 3 2-43 Tg0252-PM-SO
4. Troubleshooting after Error Message
14 01 04 EV2-AXIS ORIGIN ELEVATOR #1 ORIGIN [BPH581] SENSOR MAY BE
DEFECTIVE.
14 01 05 EV2-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
Error Code Display A Display B
14 01 06 EV2-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT OF
ELEVATOR #1 ORIGIN.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
0112-001 Chapter 3 2-44 Tg0252-PM-SO
4. Troubleshooting after Error Message
14 01 07 EV2-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
14 01 08 EV2-AXIS ORIGIN
Error Code Display A Display B
14 02 01 EV2-AXIS TIMING PREVIOUS TASK WAS NOT COMPLETED. UNABLE TO
CONTINUE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
0112-001 Chapter 3 2-45 Tg0252-PM-SO
4. Troubleshooting after Error Message
14 03 01 EV2-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
14 04 01 EV2-AXIS LIMIT LIMIT ERROR (+) IS DETECTED.;BPH582
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key to stop the buzzer sound.
(2) Press the [RESET] button to cancel the error mode.
(3) Press the [ZERO] button to return all axes to their original positions. Continue the production
according to the “WARM Start Operation Procedure”.
(4) If the device can’t be reset after the above procedure, contact our service personnel.
14 04 02 EV2-AXIS LIMIT LIMIT ERROR (-) IS DETECTED.;BPH583
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
14 04 03 EV2-AXIS LIMIT MIDDLE LIMIT ERROR (+) IS DETECTED.;BPH584
14 04 04 EV2-AXIS LIMIT MIDDLE LIMIT ERROR (-) IS DETECTED.;BPH585
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.