YV180X_Mainte_E.pdf - 第105页

4 -47 SED8013110 Service Manual Chapter 4 4 Machine adjust mode 8 Enter MCH_ADJUST mode and run the “Camera Scale” command. Select <3/3/B1 ADJUST T ARGET> − ” Moving Camera ” − ” Camera Scale ” and the conveyor tab…

100%1 / 180
4
-46
Service Manual
Chapter 4
SED8013110
4
Machine adjust mode
3. Press the [F4] key to switch to the Vision Info. sub-window and check
that the Search Area parameter is set to 4.00mm.
47437-C8-00
MARK NAME
Circle_D1.0
COMMENT
OBJ :
Vision Info.
Edit Term
Search Area mm :
No.
153
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 3/DATABASE
:
4.00
v
4 Press the [F6] key to open the Adjust Assistant screen.
The Adjust Assistant commands are used to check if the mark is clearly
recognized.
e
5 Run the FIX PCB command to clamp the PCB in place on
the conveyor.
The CONVEYOR UNIT menu box then appears, so adjust the conveyor
unit according to the size of the PCB and set the PCB on the conveyor
table. (See the mounter operation manual for how to clamp the PCB on the
conveyor table.)
6 Cancel emergency stop, then perform teaching for the
mark position with the TEACH MARK command.
Manipulate the YPU joystick to align the center of the mark with the cross
cursor on the vision monitor.
43417-C0-00
7 Run the VISION TEST command.
When no errors occur, the current parameter settings are appropriate.
Close the Adjust Assistant mode, save the settings and advance to the next
step.
If an error occurs, use the PARAM SEARCH command to find the optimum
threshold lighting level, or adjust the moving camera lighting pattern and/
or mark information parameters as necessary. (For more details on the
parameter settings, refer to the mounter operation manual.)
4
-47
SED8013110
Service Manual
Chapter 4
4
Machine adjust mode
8 Enter MCH_ADJUST mode and run the “Camera Scale”
command.
Select <3/3/B1 ADJUST TARGET>Moving CameraCamera Scale
and the conveyor table.
47439-D8-00
B1 ADJUST TARGET
Object
Moving Camera
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 3/MCH_ADJUST
<COMMAND_LIST> B/SAVE & QUIT
Target
FOV & Focus
Brightness
Camera Scale
table
A table
B table
9 Enter the mark database No. and press the [ENTER] key.
Here, enter the database No. of the mark on the PCB you are using.
(If you are using a glass PCB, enter 281.)
47440-C0-00
Mark No. 153
A420
This procedure adjusts the vertical (Y) and horizontal (X)
scales of the moving camera. A fiducial mark is used
for this adjustment. It is recommended . . .
0 Check that “Distance (mm/10) 20” is displayed, and press
the [ENTER] key.
The camera scale is calibrated while moving the head assembly in the XY
directions. Use the default setting 20.
47441-C0-00
Distance (mm/10) 20
A423
The axes will move and the fiducial mark will be
recognized in three different positions. Enter a
head movement distance . . .
q Clamp the PCB on the conveyor.
Use the commands in the CONVEYOR UNIT menu box that appears on
the screen.
When the PCB has already been clamped, skip this step.
w Select “RETURN” from the CONVEYOR UNIT menu box
and press the [ENTER] key.
You can also use the [ESC] key to exit the CONVEYOR UNIT menu.
If you have set emergency stop in the previous step, release the emergency
stop button and press the [READY] button.
4
-48
Service Manual
Chapter 4
SED8013110
4
Machine adjust mode
e Check safety, then press the [ENTER] key again.
The head assembly moves to above the PCB origin and the teaching
screen appears as shown below.
47442-C0-00
A428
<<Teaching>>
Please position the cross hair cursor over the
fiducial mark on screen......
r Position the fiducial mark in the center of the screen.
Manipulate the YPU joystick to align the mark with the cross cursor on the
screen.
43417-C0-00
t Press the [ENTER] key to start calibration.
The moving camera moves in both X and Y directions. The camera scale is
calibrated based on the amount of movement on the vision monitor and
the results are then displayed on the screen.
47443-D8-00
<<<RESULT>>>
The results of the moving camera scale adjustment are
as follows.
To save the results in memory, press the [ENTER] key
(the results are . . .
Scale_x
Scale_y
Angle
=
=
=
10.30
10.30
0.05
<<MODE>> 3/MCH_ADJUST
A431
y Check that the results are within the specified range.
When the moving camera height and angle are correctly adjusted, the
camera scale and angle should be within the specified range. If not, you
will need to readjust FOV & focus and then recalibrate the camera scale
to check the results. again.
Specified range of moving camera scale and angle
45405-D8-00
Parameter
Scale x
Scale y
Angle r
Specified Range
10.2±0.2µm (10.0 to 10.4µm)
10.2±0.2µm (10.0 to 10.4µm)
0±0.5°