YV180X_Mainte_E.pdf - 第140页
Chapter 6 Conveyor unit and air supply unit adjustment This chapter explains how to adjust the conveyor units used to transfer and clamp PCBs, and also how to set the optimum air pressure for pneumatic-driven units. 1. A…

5
-10
Service Manual
Chapter 5
SED8013110
5
Manual mode
3.5 Exit from manual
<3/4/B0>
Run the <3/4/B0 EXIT FROM MANUAL> command to exit MANUAL
mode.
EXIT FROM MANUAL command
47513-C0-00
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 4/MANUAL
<COMMAND_LIST> A/IO_UTILITY B/SERVO_CONTROL
B0 EXIT FROM MANUAL

Chapter 6
Conveyor unit and air supply
unit adjustment
This chapter explains how to adjust the conveyor units used to
transfer and clamp PCBs, and also how to set the optimum air
pressure for pneumatic-driven units.
1. Adjusting the conveyor unit 6-3
1.1 Adjusting the air valve................................................................................6-4
1.2 Conveyor speed .........................................................................................6-6
1.3 Adjusting the conveyor belt tension ...........................................................6-9
1.4 Adjusting the W-axis initial position .........................................................6-10
1.5 Y-axis (A/B table) initial position............................................................... 6-11
1.6 PCB detection sensors ..............................................................................6-13
2. Air supply unit 6-16
2.1 Air pressure regulator ...............................................................................6-16
2.2 Pressure-drop detection level ...................................................................6-17

6
-3
SED8013110
Service Manual
Chapter 6
6
Conveyor unit and air supply unit adjustment
1. Adjusting the conveyor unit
Each mechanism of the conveyor unit is arranged along the conveyor rails
and operates by air pressure or a servo motor. These conveyor units are
preadjusted at the factory prior to shipping. If for some reasons adjustment
becomes necessary, refer to the description in this section.
Conveyor units (right-to-left flow)
43601-D8-00
Pushup plate
Edge clamp (option)
Pushup pin
Entrance stopper
Movable locate pin
Fixed locate pin
Direction of PCB flow
B table conveyorA table conveyor
Exit stopper
Main stopper
PCB clamp
Carry-out conveyor
Carry-in conveyor