2.1 PREVIOUS INTERFACE circuit
When the following three conditions are met, the PREVIOUS
INTERFACE circuit in the mounter allows the next PCB to be carried in.
1. Machine is ready for carrying in a PCB (BUSY OUT: ON)
2. PCB carry-in signal is input from the upstream machine.
(BA IN [N1115]: ON)
3. Automatic operation signal is input from the upstream machine.
(UR IN [N1117]: ON)
n
Note
• When the automatic operation signal (UR IN) from the upstream machine turns off
during
transfer of a PCB, the machine temporarily stops carrying in the PCB.
• When the PCB being carried in is detected by the entrance sensor, the BUSY OUT signal
turns off.
• Carrying in the PCB is finished when both the BUSY OUT and BA IN turn off.
PREVIOUS INTERFACE circuit
43802-C0-00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
5V
10.5kΩ
0.1µ
N1115
+24V
5V
10.5kΩ
0.1µ
N1117
Upstream
machine
LR OUT
(T1837)
GND
BUSY OUT
(T1831)
GND
+24V
CONNECTION
BOARD
I/O BOARD
CONNECTION
BOARD
I/O BOARD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Cable
14
11
12
7
4
8
3
1
PREVIOUS INTERFACE
connector
This machine

8
-8
Service Manual
Chapter 8
SED8013110
8
Power and machine connections
PCB transfer signal specifications
45802-C0-00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BUSY OUT (T1832)
BUSY OUT (T1831)
BA IN (+24V)
BA IN (N1115)
NC
NC
NC
NC
UR IN (+24V)
UR IN (N1117)
LR OUT (T1837)
LR OUT (T1837)
NC
NC
Pin No.
Signal name
I/O specifications Signal specifications
Relay contact (zero voltage)
output
Relay contact (zero voltage)
output
+24V
Tr input
+24V
Tr input
Relay contact (zero voltage)
output
Relay contact (zero voltage)
output
Signal output during PCB
carry-in
Signal input of PCB
carry-out request
Signal input during
automatic operation
Signal output during
automatic operation

8
-9
SED8013110
Service Manual
Chapter 8
8
Power and machine connections
2.2 NEXT INTERFACE circuit
When the following three conditions are met, the NEXT INTERFACE
circuit in the mounter allows the PCB to be carried out.
1. Machine is ready for carrying out the PCB (BA OUT: ON)
2. PCB carry-in signal is input from the downstream machine.
(BUSY IN [N1113]: ON)
3. Automatic operation signal is input from the downstream machine.
(LR IN [N1116]: ON)
n
NOTE
• When the automatic operation signal (LR IN) from the downstream machine turns off
during
transfer of a PCB, the machine temporarily stops carrying out the PC.
• When the PCB being carried out is detected by the exit sensor, the BA OUT signal
turns off.
• Carrying out the PCB is finished when both the BUSY IN and BA OUT turn off.
NEXT INTERFACE circuit
43803-C0-00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
5V
10.5kΩ
0.1µ
IN
(N1120)
This machine
+24V
5V
10.5kΩ
0.1µ
BUSY IN
(N1113)
Downstream
machine
BA OUT
(T1832)
GND
UR OUT
(T1833)
GND
+24V
CONNECTION
BOARD
I/O BOARD
CONNECTION
BOARD
I/O BOARD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Cable
NEXT INTERFACE
connector
14
11
12
7
4
8
3
1
+24V
5V
10.5kΩ
0.1µ
COUNT RESET
(N1116)