YV180X_Mainte_E.pdf - 第49页

3 -12 Service Manual Chapter 3 3 Machine data edit mode 4. Machine When “ Machine ” is selected from the <3/2/MCH_D A T A> main menu, the submenu appears as sho wn belo w . Each item on this submenu is explained in…

100%1 / 180
3
-11
Service Manual
Chapter 3
SED8013110
3
Machine data edit mode
3.2 Vision parameter
Selecting Vision Parameter from the Camera submenu opens the
Vision Parameter screen as shown below. Data entered here are vision
parameters used to perform image processing.
Vision Parameter screen
47310-D8-00
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
X
10.465
0.000
48.828
0.000
0.000
0.000
-3.606
10.489
0.000
OBJECT
Vision Parameter
TCH.UNIT SPEED
- - - - - - - -
Y
10.399
0.000
48.809
0.000
0.282
0.000
1.001
10.428
0.000
Speed
1100.000
1100.000
0.000
0.065
1100.000
Div.
12PULS
8PULS
12PULS
Object
Camera 1 Scale
Camera 2 Scale
Camera 3 Scale
Camera 4 Scale
Camrea 2 Delta Scale
Camera 3 Delta Scale
Camera 4 Delta Scale
Camera 2 Delta pos.
Camera 3 Delta pos.
A
A
A
A
A
A
A
A
A
Main
128
Coax.
40
SIde
90
Object Shows camera numbers and parameter. Camera
numbers. used here are identical with those shown
on the Coordinate/Spec screen.
Scale - X, Y XY measurement (in microns) equivalent to one
pixel, used as a camera scale.
Scale - Speed Speed at which the head moves above the camera
during component recognition.
Delta Scale X, Y Camera scale offset for correcting the fact that a
thicker component appears larger than a thinner
component of the same size. (in microns)
Delta pos. - X, Y Positional offset for a deviation of the nozzle center
relative to the camera center, which occurs if the
nozzles vertical axis is not perfectly perpendicular
to the camera.
Delta pos. - Speed Offset for a positional shift caused by dual-direction
recognition.
Scale - Div. Division pulse at which the head moves above the
camera during component recognition.
Main Main lighting level for multi camera
Coax. Coaxial lighting level for multi camera
Side Side lighting level for multi camera
n
NOTE
Vision parameters can be automatically adjusted by running the Camera Scale command
in MCH_ADUST mode.
3
-12
Service Manual
Chapter 3
3
Machine data edit mode
4. Machine
When Machine is selected from the <3/2/MCH_DATA> main menu, the
submenu appears as shown below. Each item on this submenu is explained
in the following sections.
Submenu box when Machine is selected
47311-C0-00
SUB MENU
FeederPlateOffse
Software Limit
Position
MCHDATA SORT
Head
Camera
Machine
Tray Changer
Station
Other
Precision
Spare Data
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
3
-13
Service Manual
Chapter 3
SED8013110
3
Machine data edit mode
4.1 Feeder plate offset
Current feeder plate settings and reference feeder positions can be checked
here. Teaching of the reference feeder positions can also be performed.
Feeder plate offset screen
47312-D8-00
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
X
-183.016
489.650
617.580
745.660
891.490
0.000
0.000
OBJECT
FeederPlateOffset
TCH.UNIT SPEED
- - - - - - - -
Z
17.310
17.140
17.140
17.140
17.180
0.000
0.000
DatumNo.
2
10
18
26
30
0
0
Total
8
8
8
4
8
0
0
Plate No.
FeederPlate 1
FeederPlate 2
FeederPlate 3
FeederPlate 4
FeederPlate 5
FeederPlate 6
FeederPlate 7
Plate No. Feeder plates of this machine are divided into
blocks. In each of these blocks, a reference feeder
position is specified. The plate No. listed here
represents each block on the feeder plates. (Note
that Plate No. is different from feeder set numbers.)
Total Total number of feeder set positions that are allotted
to each block on the feeder plates. On standard
YV180X, the total figure should be 40 for each of
the front and rear feeder plates.
DatumNo. Feeder set number specified as a reference feeder
position. Any feeder set number within the block
can be specified as a reference feeder position.
X, Z Component pickup position and height (mm) when
a standard 8mm tape feeder is installed in the
reference feeder position.