4
-57
SED8013110
Service Manual
Chapter 4
4
Machine adjust mode
9 Cancel emergency stop and press the [ENTER] key.
The head assembly moves and passes repeatedly over the multi-vision
camera and the side brightness level is automatically measured and
optimized.
The lighting unit of the selected camera flashes at this time.
0 Quit the adjustment.
Follow the messages displayed on the operation monitor to quit the
adjustment and remove the focus adjuster plate. There is no machine data
to be saved in this adjustment.
Typical range of multi-vision camera lighting levels
45408-D8-00
Lighting method
Main
Coaxial
Side
Reference Value
128±1
40±1
90±1
4
-58
Service Manual
Chapter 4
SED8013110
4
Machine adjust mode
3.5.3 Calibrating the multi-vision camera scale
The multi-vision camera scale represents an actual measurement (in
microns) equivalent to one pixel. This scale must be calibrated correctly
for accurate recognition of components.
To calibrate the camera scale, you will need an SOP or QFP of known size.
When you run the adjustment utility described below, the camera scale is
automatically calibrated and the XY positions and installation angle R of
the camera are also adjusted at the same time.
1 Prepare a component to be used as a reference.
Use a relatively large, popular SOP or QFP of known size which is
registered in the component database. If using tape feeder components, set
the tape feeder on the feeder plate in advance.
Reference
YAMAHA uses a glass QFP with minimal warp and distortion, specially designed for
adjustment work. To make more accurate adjustments, we recommend using this glass
QFP (sold separately).
2 Edit Search Area mm in the component data.
Data registered in the database as a number larger than No.500 cannot be
edited due to write-protection. Make a copy of the data using a number
smaller than No.500, then edit this data. For instance, the following steps
are explained for cases where SOP data is copied onto registration No. 2.
If using a glass QFP (database No. 996), skip this step.
1. Open component database and line up the cursor with component No.
2.
2. Press the [TAB] and [F4] keys to switch the sub-window to VISION
INFO. and change the Search Area value to 9.99 (maximum setting).
Since the camera scale is measured while moving the component
slightly, this change compensates for that movement.
47447-C0-00
9.99
COMPONENT NAME
Sample_SOP16-P1.27
COMMENT
example_data
OBJ :
5.VISION INFO.
Search Area
No.
1
2
3
4
5
6
7
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 3/DATABASE
:
4
-59
SED8013110
Service Manual
Chapter 4
4
Machine adjust mode
3. Press the [F4] key to switch the sub-window to BASIC INFO. and
change the Comp. Package parameter to Tray if you want to attach
the component to the nozzle by hand during this adjustment. Leave this
parameter unchanged (Tape ) when you are going to use a tape
feeder.
47448-C0-00
Tray
COMPONENT NAME
Sample_SOP16-P1.27
COMMENT
example_data
OBJ :
1.BASIC INFO.
Comp. Package
No.
1
2
3
4
5
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 3/DATABASE
:
e
3 Press the emergency stop button, then attach an appropri-
ate nozzle to Head 1.
Use a Type 73A or 74A nozzle for this adjustment. (If using a glass QFP,
attach Type 74A.)
4 Run the Adjust Assistant to check that the component is
recognized.
1. Cancel emergency stop and enter the Adjust Assistant mode.
2. Run the PICK UP COMP VISION TEST commands and, if
necessary, adjust the parameter values. (For details on the Adjust Assistant,
refer to the mounter operation manual.) You can leave the component
attached to the nozzle even after finishing the Adjust Assistant.
5 Save the edited data.
Press the [ESC] key twice, then select <C0 SAVE & EXIT> and press the
[ENTER] key.
6 Run the Multi CameraCamera Scale command.
1. Select <3/3/B1 ADJUST TARGET>Multi CameraCamera Scale
and press the [ENTER] key.
2. Select the conveyor table and the camera No. by pressing the [ENTER]
key.
The A-table multi-vision camera is designated Cam. 5 and the B-table
multi-vision camera Cam. 6.
47445-D8-B0
B1 ADJUST TARGET
Object
Multi Camera
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 3/MCH_ADJUST
<COMMAND_LIST> B/SAVE & QUIT
Target
FOV & Focus
Brightness
Camera Scale
Dual Recognition
Marker
table
A table
B table
Target
Cam. 1
Cam. 2
Cam. 3
Cam. 4
Cam. 5
Cam. 6
Cam. 7
Cam. 8
A Table
Multi Camer
a
B Table
Multi Camer
a