YV180X_Mainte_E.pdf - 第89页

4 -31 SED8013110 Service Manual Chapter 4 4 Machine adjust mode T -axis Speed This parameter specifies the PCB transfer hook (T -axis) mov ement speeds during automatic operation. 47421-D8-A0 X -28.280 -28.280 562.000 25…

100%1 / 180
4
-30
Service Manual
Chapter 4
SED8013110
4
Machine adjust mode
T-axis Distance
During automatic operation, the PCB transfer hook (T-axis) first moves at
high speed and then switches to a low speed for minimizing impact when
the PCB hits the main stopper. This transfer hook movement during
automatic operation can be specified here.
This is a reference stroke of the T-axis when it transfers a PCB.
47421-D8-00
X
-28.280
-28.280
562.000
255.916
0.500
100.000
130.000
0.000
10.000
100
Object
FINE mode
Locate pin
Edge Clamp
Wait point
Discard point
PCB Height
Simul. pickarea
QFP clearance
Retry Limit.
Dump station1
Dump station2
Fiducial cor.
T-axis Distance
T-axis Speed
Type
NORMAL
100
DUMP
4.00
NO RETRY
2.00
2.00
Nouse
OBJECT
Position
TCH. UNIT SPEED
- - - - - - - -
A
A
A
A
A
A
A
A
A
A
A
Y
0.005
118.810
118.810
0.000
71.321
0.5000
150.000
210.000
0.000
30
Z
0.000
0.000
17.480
0.500
16.000
16.000
0.000
10.000
20
R
0.000
0.000
0.000
0.000
17.480
0.200
0.000
10.000
Feeder
100
0
0
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
X Margin for the position at which the PCB transfer hook
descends to begin carrying the PCB on the conveyor. This
setting can be 10.0 to 50.0 (mm). For example, when 30 is
entered here, the transfer hook descends at a position 30mm
away back from the upstream edge of the PCB. During
standard right-to-left flow, the machine coordinate of the
hook descent position is given by
Hook descent position
= [T-axis initial position] + [PCB length]+ [this value]
Z Position at which the PCB transfer hook speed switches to a
low speed before the PCB hits the main stopper. This setting
can be 10.0 to 50.0 (mm). For example, when 30 is entered
here, the transfer hook speed switches to a low speed at a
position 30mm before the main stopper.
R Distance (mm) by which the PCB transfer hook moves back
to a position to ascend, after the PCB is clamped on the
conveyor table.
4
-31
SED8013110
Service Manual
Chapter 4
4
Machine adjust mode
T-axis Speed
This parameter specifies the PCB transfer hook (T-axis) movement speeds
during automatic operation.
47421-D8-A0
X
-28.280
-28.280
562.000
255.916
0.500
100.000
130.000
0.000
10.000
100
Object
FINE mode
Locate pin
Edge Clamp
Wait point
Discard point
PCB Height
Simul. pickarea
QFP clearance
Retry Limit.
Dump station1
Dump station2
Fiducial cor.
T-axis Distance
T-axis Speed
Type
NORMAL
100
DUMP
4.00
NO RETRY
2.00
2.00
Nouse
OBJECT
Position
TCH. UNIT SPEED
- - - - - - - -
A
A
A
A
A
A
A
A
A
A
A
Y
0.005
118.810
118.810
0.000
71.321
0.5000
150.000
210.000
0.000
30
Z
0.000
0.000
17.480
0.500
16.000
16.000
0.000
10.000
20
R
0.000
0.000
0.000
0.000
17.480
0.200
0.000
10.000
Feeder
100
0
0
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
X Speed at which the PCB transfer hook moves back to the PCB
transfer start position and moves away from the PCB after it
has been clamped on the conveyor table.
Y1 Higher speed at which the PCB transfer hook carries the PCB.
This setting can be from 10 to 100%.
Z Lower speed at which the PCB transfer hook carries the PCB.
This setting can be from 10 to 100%.
4
-32
Service Manual
Chapter 4
SED8013110
4
Machine adjust mode
Conv. Correct 1 to 4
These parameters are used to correct the conveyor surface for non-flatness
(uneven height with position). The positions (XY) at 4 points on the
conveyor table (see below) and their heights (Z) are entered here, with the
conveyor rails widened to its maximum. To re-enter these coordinates, refer
to the teaching procedure for PCB height.
47422-D8-00
X
-28.280
-28.280
562.000
255.916
0.500
100.000
130.000
0.000
10.000
100
-9.709
312.105
312.105
-44.554
Object
FINE mode
Locate pin
Edge Clamp
Wait point
Discard point
PCB Height
Simul. pickarea
QFP clearance
Retry Limit.
Dump station1
Dump station2
Fiducial cor.
T-axis Distance
T-axis Speed
Conv Correct1
Conv Correct2
Conv Correct3
Conv Correct4
Type
NORMAL
100
DUMP
4.00
NO RETRY
2.00
2.00
Nouse
OBJECT
Position
TCH. UNIT SPEED
- - - - - - - -
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Y
0.005
118.810
118.810
0.000
71.321
0.5000
150.000
210.000
0.000
30
110.195
110.194
290.522
290.441
Z
0.000
0.000
17.480
0.500
16.000
16.000
0.000
10.000
20
17.438
17.460
17.493
17.512
R
0.000
0.000
0.000
0.000
17.480
0.200
0.000
10.000
Feeder
100
0
0
<<<APPLICATION>>> 3/MAINTE/M
<<MODE>> 2/MCH_DATA
Conveyor height correction points
43407-D8-00
++
++
M type: 330mm
L type: 380mm
Main stopper
Maximum PCB length
Maximum
PCB widt
h
Conveyor rail
43
1
2
1 - 4:Teaching points