4-12 4 Daily operation 6. Refilling the cleaning solvent 6.1 Precautions when handling cleaning solvent w W ARNING USE ONL Y ISOPROPYL ALCOHOL OR ETHYL ALCOHOL (ETHANOL) AS THE CLEANING SOL VENT. OTHER SOL VENTS MA Y CAU…

100%1 / 288
4-11
4
Daily operation
n
Machine setting when replacing the cleaner width change unit (option)
When replacing the cleaner width change unit (option), "Cleaner Width" of the machine setting needs to be changed.
c
CAUTION
· To change the machine setting, the administrator authority is required.
· Do not change any parameter as each parameter of the machine setting has been set at shipment (or at installation).
· When changing the cleaner width, refer to the descriptions shown below.
1. Press the [Machine] button on the operation screen to open the "VmSpec" window.
2. Click [Setting] - [Machine Data] - [Cleaner Setting] - [Basic Setting].
3. Set "Cleaner Width".
Select a size of the replaced cleaner width change unit from the drop down list.
4. Click the close button at the upper right corner of the screen to exit the setting.
When you have changed the data, click [Yes] on the "Exit" screen.
"VmSpec" window
[Cleaner Setting]  [Basic Setting]  [Cleaner Width]
Close button
Select a size and set it.
64423-N1-00
5. When you have changed any value, load the board data again.
As the board data is loaded again, the changes are then enabled.
4-12
4
Daily operation
6. Refilling the cleaning solvent
6.1 Precautions when handling cleaning solvent
w
WARNING
USE ONLY ISOPROPYL ALCOHOL OR ETHYL ALCOHOL (ETHANOL) AS THE CLEANING SOLVENT. OTHER SOLVENTS MAY
CAUSE FIRES.
w
WARNING
NEVER USE ACETONE FOR CLEANING. ACETONE MAY DAMAGE SOLVENT TUBES OR CLEANING UNIT, CAUSING CLEANING
FLUID TO LEAK THROUGH DAMAGED PARTS. ALSO BE SURE TO USE VIRGIN CLEANING FLUID (DO NOT USE USED CLEANING
FLUID).
w
WARNING
BE CAREFUL WHEN USING ISOPROPYL ALCOHOL, SINCE INHALING ALCOHOL FUMES OVER LONG PERIODS CAN BE
HAZARDOUS TO HEALTH.
6.2 Refilling the cleaning solvent
When the fluid level in the solvent bottle is below the solvent run-out sensor, the error screen will appear and
the wet cleaning cannot be performed.
The cleaning solvent bottle is located at the lower left portion on the front of the main unit.
Follow the steps below to refill the solvent.
1
Take out the solvent bottle.
Unplug the connector while pulling the outer
ring of the connector on the machine main
unit side that is connected to the solvent
bottle.
63410-N1-00
2
Refill the bottle with solvent.
Use isopropyl alcohol or ethyl alcohol as the
cleaning solvent.
n
NOTE
Fully refill the bottle with solvent. Additionally, check
that the bottle cap is closed completely.
3
Reinstall the solvent bottle back to
its original position.
Insert the connector on the solvent bottle
cap into the mating connector on the
machine.
4
Clear the error screen and check
the status display.
Check that the yellow indication lamp on
the top of the machine and "error" display in
the status area on the operation screen
have disappeared.
Solvent bottle
Step 1
Solvent bottle Solvent run-out sensor
Unplug the connector (while pulling the outer ring).
4-13
4
Daily operation
n
NOTE
When setting the solvent bottle for the first time or when the solvent has not been used for an extended period of
time, follow the steps below to discharge the solvent to the gauze roll.
1. Select the [Cleaner] tab on the [Unit] screen.
2. Press the [Fuel Pump] button to discharge the solvent. When the solvent oozes from the gauze roll, this work is
completed.
[Unit] screen
[Cleaner] tab
[Fuel Pump] button
64408-N1-10