YCP10 Users_E.pdf - 第280页
Appendix Contents 1. Specifications A-1 1.1 Air regulator unit A-1 1.1.1 Air supply A-1 1.1.2 Edge clamp air pressure A-2 1.2 Power connection terminals A-3 1.3 Connection between machines A-4 1.3.1 PREVIOUS INTERF ACE c…

3-9
3
Lubrication points
2.5 Suction-blower unit
2.5.1 Blower hose guide
Lubrication points in suction blower unit
blower hose guide
Grease gun:
Manual lubrication:
53311-N1-00
Lubrication section Lubrication point Interval Procedure
Blower hose guide 1 (Each table)
When hose is
replaced
Manual lubrication
2.6 Cleaning unit
Lubrication points of cleaning unit
Grease nipple of Y-direction guide
Grease gun:
Manual lubrication:
53312-N1-00
Lubrication section Lubrication point Interval Procedure
Y-direction guide 2 Monthly Grease gun

A-1
Appendix
1. Specifications
1.1 Air regulator unit
1.1.1 Air supply
The air pressure regulator is located behind the front lower panel of the machine. The air pressure regulator
must be correctly set to supply the machine at an optimum air pressure.
c
CAUTION
Before setting the air pressure, make sure that the pressure from the primary air supply is within an appropriate range
(0.45MPa or less).
Air pressure regulator and air connector
Mist filter
4
31 2
5
Air filter
53A01-N1-00
1. Air pressure display
Shows the set air pressure. Use the pressure regulator knob to display the pressure levels described below.
• Set air pressure level: 0.40MPa to 0.41MPa
2 Pressure gauge (for cleaner suction)
Shows the cleaner's vacuum air pressure level (negative pressure level).
3. Supply air pressure regulator valve knob
Use this knob to adjust the supply air pressure to a proper set pressure level.
Turn the knob to adjust the supply air pressure so that the set air pressure level shows “0.40MPa”.
4. Air pressure supply/shutoff switch
Turning this switch to the right shuts off air supply and exhausts air that remains inside the machine.
5. Source air connector
Prepare an air hose with an inner diameter of at least 8 mm having a 30SH socket (Nitto Koki, or equivalent), and
connect it to this connector. Use dry, clean air passed through an air filter.