4-14 4 Daily operation 6.3 Long-term storage tasks If the solvent pump is not used for extended periods (about 6 months or more), then it ma y dry out internally and cause operating defects. T he solvent path within the …

4-13
4
Daily operation
n
NOTE
When setting the solvent bottle for the first time or when the solvent has not been used for an extended period of
time, follow the steps below to discharge the solvent to the gauze roll.
1. Select the [Cleaner] tab on the [Unit] screen.
2. Press the [Fuel Pump] button to discharge the solvent. When the solvent oozes from the gauze roll, this work is
completed.
[Unit] screen
[Cleaner] tab
[Fuel Pump] button
64408-N1-10

4-14
4
Daily operation
6.3 Long-term storage tasks
If the solvent pump is not used for extended periods (about 6 months or more), then it may dry out internally
and cause operating defects. The solvent path within the pump must be blocked to prevent this from happening.
The path blocking procedure is described below.
n
Blocking the solvent path
1
Remove the cleaner cover.
1. Remove two screws (dotted line portions
in the figure on the right) that secure the
cleaner cover.
2. Next remove the screws at 4 locations on
the near side (see drawing).
3. Raise the cover upward and then pull
toward you to remove it.
63413-N1-00
2
Remove the joints.
Remove the joints from two locations, one
on the head side and the other on the
bottle side from the shut-off valve joint. Use
caution because alcohol remaining in the
hose will come out when the joint on the
head side is removed.
1. Remove the head side joint in the bent
state as shown by the dashed line in the
figure on the right.
2. Prepare a container, free the bent
location and let the alcohol drain into
the container.
3. Remove the bottle side joint and then
quickly point it upward to let the alcohol
in the hose return back to the bottle.
63414-N1-00
3
Mark the hoses you removed.
Mark the two hose sections you removed in
step 2 by winding yellow ribbon or a similar
item around them.
63415-N1-10
4
Reattach the cleaner cover.
Reinstall the cleaner cover in the reverse of
the procedure that you removed it in step 1.
Place a ribbon on the outer side of the
cover so that others will know that the joints
were removed.
n
Resetting operation
Connect the hoses in the reverse of the "Blocking the
solvent path" procedure and refill with solvent by
referring to "6.2 Refilling the cleaning solvent" in this
Chapter. When finished refilling, operate the solvent
pump to make sure it operates correctly.
Removing the cleaner cover
Step 1
First, remove the screws at 2 locations.
Removing the joints
Step 2
Joint (to head)
Shut-off valve joint
Container
Joint (to bottle)
Hose markings
Step 3
Marking (yellow ribbon, etc.)
Marking
As seen from outside the cover

4-15
4
Daily operation
7. Compatible masks
7.1 Mask size and mask stopper pin position
The mask stopper pin position must be changed according to the mask frame size to be used as shown below.
One screw-type mask stopper pin sets the left end position of the mask frame. Screw this stopper pin into one
of the "F" positions when the front conveyor rail is fixed, or one of the "R" positions when the rear conveyor rail
is fixed.
n
Mask frame size and stopper pin position
Mask frame size
L (mm) × W(mm)
Applicable board dimensions
L (mm) × W(mm)
Mask frame stopper pin position
L direction W direction
750 × 750 L50 × W50 (min.) to L510 × W460 (max) A Not used.
750 × 650 L50 × W50 (min.) to L510 × W350 (max.) A 2 (2 locations)
736 × 736 L50 × W50 (min.) to L510 × W460 (max.) B 1 (2 locations)
650 × 550 L50 × W50 (min.) to L330 × W250 (max.) C 3 (2 locations)
600 × 550 L50 × W50 (min.) to L330 × W250 (max.) D Mask adaptor (option)*
584 × 584 L50 × W50 (min.) to L330 × W250 (max.) E Mask adaptor (option)*
550 × 650 L50 × W50 (min.) to L330 × W250 (max.) F Mask adaptor (option)*
*See "7.3 Using the mask adaptor" in this chapter for the mask adaptor (option).
TIP : Store the pins that are not in use.
A
B C DF
E
11
22
3 3
Mask frame size and stopper pin position
Mask clamp
Mask frame L
Mask frame W
63422-N1-10
Mask stopper pin
Mask stopper pin
63423-N1-00