YCP10 Users_E.pdf - 第98页
4-2 4 Daily operation 2. Star ting and war ming up the machine After starting up the machine, we recommend letting war m up for about 10 minutes. No warm-up is necessar y if less than two hours have elapsed after the mac…

4-1
4
Daily operation
1. Overview
This chapter explains typical daily operation per the flow chart shown below.
Start machine
Check before operation
Warm-up operation
Change setups
Do you change board model?
Perform rolling operation
Finish production
Start production
Turn power off
Select board
Daily operation flow
NO
YES
Execute as needed.
63401-N1-00

4-2
4
Daily operation
2. Starting and warming up the machine
After starting up the machine, we recommend letting warm up for about 10 minutes. No warm-up is
necessary if less than two hours have elapsed after the machine was last used.
1
Make pre-operation checks and then start up the machine.
For pre-operation checks and starting up the machine, see "Chapter 2 Basic operations".
2
Press the [Warm Up] button on the Setup screen.
The Warm-up screen then appears.
Setup screen
Pressing this button opens the “Warm-up” screen.
Setup screen
64401-N1-10
3
Enter a warm-up time.
Press the [Stop after time over] button and enter the warm-up time. Warm-up will automatically stop
when the warm-up time you set has elapsed. Normally, about a 10-minute warm-up is recommended.
Warm-up time setting
Press this button to set the
warm-up time.
Enter a period of the
warm-up time.
64402-N1-00

4-3
4
Daily operation
4
Press the [Start] button to start warm-up.
The warm-up progress time and status appears ion the "Warm-up" screen.
“Warm-up” screen
Warm-up elapsed time
Pressing this button will stop the
warm-up operation.
64403-N1-00
c
CAUTION
If problem occurs during warm-up, press the [Stop] button to stop operation immediately, check the cause of the
problem and eliminate it.
5
End the warm-up.
When the time reaches that set in Step 3, the machine automatically ends the operation.
(To end the warm-up operation halfway, press the [Stop] button.)
After the warm-up has been completed, press the [Close] button to return to the previous screen.