YCP10 Users_E.pdf - 第267页

2-20 2 Inspection and maintenance 3.4 Cleaning/replacing filter for mask vacuum chuck n Required tools • Phillips screwdriver • Replacement filter (KGR-M9934-F0X FIL TER, SPARE ) • Air blow tool (option) 1 Perform the re…

100%1 / 288
2-19
2
Inspection and maintenance
7
Connect the blower hose on the
base side to the vacuum pipe
temporarily.
Connect the blower hose to the vacuum
pipe temporarily.
53216-N1-00
8
Connect the blower hose on the
cleaning unit to the vacuum pipe.
1. Move the cleaning unit to the front by
hand.
2. Connect the blower hose to the joint and
tighten the hose band with a flat-blade
screwdriver to secure it.
9
Check the blower hose position
from the cleaning unit side.
Move the cleaning unit to the rear by hand.
Check that the blower hose is stored straight
above the hose guide.
0
Secure the blower hose.
Tighten the hose band of the vacuum pipe
on the base side with a flat-blade
screwdriver, and then secure it.
q
Return the cleaning unit to its
original position.
1. Return the cleaner head that has been
moved to the rear in Step 9 to its original
position.
2. Open the [Unit]-[I/O] tab and select
“CLEANER” from the “Output” drop-down
list.
3. Select “T0100002” (cleaner connection)
and press the [ON/OFF] button to set "0"
(release).
The cleaning unit is then secured.
Connecting the blower hose
Step 7
Blower hose
Vacuum pipe
Hose band
2-20
2
Inspection and maintenance
3.4 Cleaning/replacing filter for mask vacuum chuck
n
Required tools
Phillips screwdriver
Replacement filter (KGR-M9934-F0X FILTER, SPARE
)
Air blow tool (option)
1
Perform the return-to-origin.
After checking the safety, press the [Origin]
button on the Setup screen.
The printing table moves to the rear.
2
Press the emergency stop button.
To ensure the work safety, be sure to put the
machine in the emergency stop status.
e
3
Remove the rear cover.
Remove the cover mounting bolts (6 pcs.)
with a Phillips screwdriver to detach the
cover.
4
Remove the filter unit.
Remove the filter unit from the air hose.
53213-N1-00
5
Take the filter out of the filter unit.
Turn the joint cap, which has marks L (Lock)
and O (Open) on it, to the “O” direction and
take the filter out of the transparent case.
6
Clean the filter.
Use the air blow tool to blow away dust and
impurities trapped in the filter, by blowing air
from the inside and also from the outside. If
the filter is excessively dirty and cannot be
cleaned, replace it with a new filter.
7
Reattach the filter unit.
1. Put the filter into the transparent case
and tighten the removed joint cap by
turning it to the “L” direction.
2. Connect the air hose so that the arrow
mark (
) on the filter unit is located on
the ejector side.
Filter unit
Step 4,5
Backup unit
joint cap
Filter Transparent case
Filter unit
L and O marks
2-21
2
Inspection and maintenance
3.5 Replacing the conveyor transfer belt
If significant looseness, contamination, or scuffing is found in the conveyor transfer belt in a periodic
inspection, the conveyor belt (hereafter "belt") needs to be replaced. Follow the steps below to replace belt.
n
Required tools
Hex wrench (2.5 mm, 3 mm, 4 mm, 5 mm)
Permanent marker
• Brush
Plastic spatula
Replacement conveyor transfer belt (KLV-M9127-00X BELT CONVEYOR) (for Type A)
Replacement conveyor transfer belt (KLV-M9127-01X BELT CONVEYOR) (for Type B)
1
Prepare for detaching belt.
See Step 1 to 3 in "2.3.1 Belt Type A" to
detach mask guide plate.
2
Mark the tension mounting position
before adjusting.
<Type A>
Mark the tensioner mounting bolt position
with permanent marker.
<Type B>
Mark the tension adjustment plate position
with permanent marker.
53214-N1-20
3
Loosen the belt tension.
<Type A>
Loosen pulley with 2 hex wrenches. Move
the pulley to the end of slot (black arrow's
direction shown at right).
<Type B>
Loosen tension adjustment plate mounting
bolts with hex wrench and move tension
adjustment plate in black arrow's direction
shown at right.
4
Detach the belt.
1. Loosen the coupling mounting bolt with
hex wrench (2.5 mm) to slide the
coupling to the machine rear side.
2. Detach the belt from pulley and pull it
from the gap between pulley and shaft.
Marking / Loosening belt
Step 2, 3
Tensioner (pulley)
Tensioner (pulley)
mounting bolt
Hex wrench
(4 mm)
Marking
Marking
<Type A>
<Type B>
Hex wrench
(5 mm)
Tension adjustment plate
mounting bolt
Tension adjustment plate
Hex wrench (3 mm)
Detaching the belt
Step 4
Coupling
Hex wrench (2.5 mm)
Slide to machine rear side.
Gap to pull out belt