YCP10 Users_E.pdf - 第258页
2-11 2 Inspection and maintenance 2.5 Inspecting and cleaning the air/mist filters Air/mist filters are used to prevent oil, mist and other impurities in the air compressor from penetrating into the machine. T hese filte…

2-10
2
Inspection and maintenance
2.3.2 Belt Type B
1
Prepare for tension adjustment.
See Step 1 to 3 in "2.3.1 Belt Type A" to
detach mask guide plate.
2
Loosen the belt tension.
1. Mark the current position of tension
adjustment plate with permanent marker
before loosening the belt.
2. Loosen 2 bolts on tension adjustment
plate with hex wrench (3 mm). Then
loosen the belt.
53231-N1-00
3
Tighten the tension adjustment
plate temporarily.
If applying tension strongly, slide the
tightening position to black arrow's direction
shown at right. Sliding it to white arrow's
direction loosens the tension.
53232-N1-00
4
Measure the belt tension.
Measure the position shown in the figure
Step 4 with tension meter.
The following is the appropriate value.
Tension value: 24 to 34 N (256 to 305Hz)
53233-N1-00
5
Adjust the belt position.
Adjust the belt tension according to the belt
tension measurement result until the value
falls within the specified value.
n
NOTE
Make sure to use tension meter when adjusting the
tension.
6
Tighten the tension adjustment
plate bolts.
Tighten the tension adjustment plate bolts
after the belt tension enters the appropriate
range.
7
Check belt rotating condition and
return mask guide plate to original
position.
See Step 11 to 12 in "2.3.1 Belt Type A" to
check and return the conveyor.
Loosening belt tension
Step 2
Tension adjustment plate
mounting bolt
Hex wrench (3 mm)
Conveyor belt
Mark here before adjustment.
Tightening tension adjustment plate
temporarily
Step 3
Tension adjustment
mounting bolt
Tension adjustment plate
Hex wrench (3 mm)
Measuring tension (exit side)
Step 4
Measure here.WEIGHT :2.5 g/m
WIDTH :6 mm
SPAN :78 mm
Tension meter set value:
24 to 34 N (256 to 305Hz)
Tension value:

2-11
2
Inspection and maintenance
2.5 Inspecting and cleaning the air/mist filters
Air/mist filters are used to prevent oil, mist and other impurities in the air compressor from penetrating into the
machine. These filters should be inspected and cleaned periodically as instructed below.
c
CAUTION
The air coupler should be disconnected to safely perform the work. When disconnecting it, be careful not to allow oil,
water, or impurities to splash outward. Also take care since a large air exhaust sound is produced when disconnecting
the air coupler.
n
Required tools
• Neutral detergent
• Air blow tool (option)
• Cleaning rag
• Replacement air filter (KLC-M8506-00X FILTER ELEMENT)
• Replacement mist filter (LG0-M86A2-10X MIST FILTER ELEMENT)
c
CAUTION
When performing air blow, wear dust-proof goggles and mask to protect your face from blown dust, etc.
n
Cleaning the filter cup
1
Check the inside of the filer cup.
Check for oil or water deposits in the filter
cup through the window. If the window is
dirty, follow the steps below to clean the
filter cup.
TIP
The drain cock at the bottom of the filter cup is an
auto-drain type. It automatically drains the oil or water
when deposited in the cup. We recommend
connecting a hose to this drain cock.
2
Remove the filter cup.
While pressing the button on the side of the
filter cup, turn it clockwise, and pull the filter
cup downwards. The cup you have removed
has a double structure. The inner transparent
cup should be cleaned.
53204-N1-00
3
Clean the inside of the filter cup.
1. Lightly clean the filter cup with water.
2. Then, pour water-diluted neutral
detergent into the filter cup and clean
the inside while shaking it.
3. Air blow the filter cup and wipe away
any moisture with clean cloth or paper.
4
Reattach the filter cup.
Install the oil mist filter.
1. Adjust the button on the cup to the
position where the filter has been
removed. Push the cup upward.
2. Turn the cup clockwise until a click sound
is heard.
Install the air filter
Turn the cup clockwise until a click sound is
heard.
Removing the filter cup
Step 2
Filter cup
Disconnect the
air coupler.
Air filer
Button
Oil mist filter

2-12
2
Inspection and maintenance
5
Reconnect the air hose to the air
coupler.
After connecting the air hose, check that no
air is leaking.
n
NOTE
Leave the filter cup removed to clean the air filter as
explained in the next procedure.
n
Cleaning the air/mist filters
1
Remove the filter cup.
See the previous procedure in "Cleaning the
filter cup".
2
Remove the filter.
Remove the filter by turning it.
53205-N1-00
3
Clean the filter element.
Use an air blow gun to blow away dust and
impurities trapped by the filter element. If
the filter is excessively dirty and cannot be
cleaned, replace it with a new filter.
4
Reattach the filter.
5
Reattach the filter cup.
6
Reconnect the air hose to the air
coupler.
After connecting the air hose, check that no
air is leaking.
Removing thefilter
Step 2
MIST FILTER ELEMENTFILTER ELEMENT