A-4 Appendix 1.3 Connection between machines T o exchange signals such as board request and oper ation status with the downstream or upstream machine, the "NEXT INTERF ACE" and "PREVIOUS INTERF A CE" …

A-3
Appendix
1.2 Power connection terminals
When opening the panel at the lower portion on the front of the main unit, you can see the power connection
terminals. Use the power cable shown in the figure below to connect the power cable leads to the primary
terminals L1 and L2 on the main breaker and the ground terminal on the main unit chassis.
n
Power supply specifications
Power Single-phase AC 200 / 208/ 220 / 230V ±20V
Frequency 50/60Hz
Power capacity 6.9KVA (excluding optional air conditioner)
c
CAUTION
When installing an earth leakage breaker on the host unit, its sensitivity current must be 30mA or more.
Power input terminal
Power input terminal M5
Terminal blocks
Main breaker
L1 L2 PE
53A03-N1-10
Connecting power cables (example)
L1
L M5
L2
N M5
Ground (green)
L = 350 mm
Crimp ring terminal M5
53A04-N1-10
c
CAUTION
Use a power cable with a grade of cross-sectional area of the conductor is 6.0 mm2 or more.
Make sure that the power cable connections are correct. If misconnected, the vacuum operation of the suction unit
will be reversed (air blows outward).
w
WARNING
TO AVOID THE RISK OF ELECTRICAL SHOCK, MAKE SURE THAT THE POWER SOURCE IS OFF BEFORE CONNECTING THE
POWER CABLE. ALSO MAKE SURE THAT THE GROUND CABLE IS SECURELY CONNECTED TO THE MACHINE.

A-4
Appendix
1.3 Connection between machines
To exchange signals such as board request and operation status with the downstream or upstream machine, the
"NEXT INTERFACE" and "PREVIOUS INTERFACE" connectors located on both sides of the machine are used.
The "NEXT INTERFACE" connector connects to the downstream machine, and the "PREVIOUS INTERFACE"
connector connects to the upstream machine such as the loader. In the case of standard right-to-left flow, the
PREVIOUS INTERFACE connector is located on the left side of the rear panel, and the NEXT INTERFACE
connector is located on the right side. Both connectors use a 14-pin receptacle (AMP 206043-1).
Machine-to-machine interface connectors
Inside the panel at the lower portion of the rear
Connector : AMP 206043-1 (14-pin receptacle)
NEXT INTERFACE
14
11
12
7
4
8
3
1
PREVIOUS INTERFACE
14
11
12
7
4
8
1
3
53A05-N1-00

A-5
Appendix
1.3.1 PREVIOUS INTERFACE connector
When the following three conditions are met, the PREVIOUS INTERFACE circuit in the machine allows the next
board to be carried in.
1. Machine is ready for carrying in a board (BUSY OUT: ON)
2. Board carry-in signal is input from the upstream machine. (BA IN [N0100321]: ON)
3. Automatic operation signal is input from the upstream machine. (UR IN [N0100322]: ON)
n
NOTE
• When the automatic operation signal (UR IN) from the loader turns off during transfer of a board, the machine
temporarily stops carrying in the board.
• When the board being carried in is detected by the entrance sensor, the BUSY OUT signal turns off.
• Carrying in the board is finished when both the BUSY OUT and BA IN turn off.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BUSY OUT
(T01000E4)
+24V
+24V
LR OUT
(T01000E7)
UR IN
(N0100322)
BA IN
(N01000321)
Signal input during
board carry-in
Signal output to
request board
carry-out
Signal output during
automatic operation
Signal input during
automatic operation
I/O BOARD
7
12
4
8
1
14
11
3
PREVIOUS INTERFACE circuit
PREVIOUS INTERFACE on this machineUpstream machine
PREVIOUS INTERFACE
connector
AMP 206043-1
(14-pin receptacle)
53A06-N1-00
n
Board transfer signal specifications (PREVIOUS INTERFACE)
Pin No. Signal name Address I/O specifications Signal specifications
1 BUSY OUT T01000E4 Relay contact output
Signal output during board carry-in
2 BUSY OUT T01000E4 Relay contact output
3 +24V Input common (+24V)
Signal input to request board carry-out
4 BA IN N0100321 Voltage input
5 NC
6 With dummy pin Prevents misinsertion
7 NC
8 NC
9 +24V Input common (+24V)
Signal input during automatic
operation
10 UR IN N0100322 Voltage input
11 LR OUT T01000E7 Relay contact output
Signal output during automatic
operation
12 LR OUT T01000E7 Relay contact output
13 NC
14 NC