3OM-1003-005.pdf - 第116页
(2) "U-N" in "P .E.C. recognition mode image" T ext Box Fig. 3B95 Example of T wo Units • Set parameters in the "Recog Coord X1 [mm]", "Recog Coord Y1 [mm]", "Recog Coord X2 […

Recog Coord X1 [mm] and Recog Coord Y1 [mm]
Set the X1 and Y1 coordinates of the first fiducial mark based on the
pattern origin.
Unit: mm
Recog Coord X2 [mm] and Recog Coord Y2 [mm]
Set the X2 and Y2 coordinates of the second fiducial mark based on
the pattern origin.
Unit: mm
Fiducial Mark FM1 and Fiducial Mark FM2
Set the mark Nos. of the first and second fiducial marks FM1 and FM2.
Select the mark Nos. (Mark #) specified in the P.C.B. recognition mark
data of the operation data.
Recog Coord X1 [mm]
Recog Coord Y1 [mm]
010.000
010.000
Fig. 3B92
Fig. 3B93
Recog Coord X2 [mm]
Recog Coord Y2 [mm]
100.000
100.000
0305-001 2-46 AIL01EDTP
Fig. 3B94
Fiducial Mark FM1
Fiducial Mark FM2
01
01
2.5 Placement Data

(2) "U-N" in "P.E.C. recognition mode image" Text Box
Fig. 3B95 Example of Two Units
• Set parameters in the "Recog Coord X1 [mm]", "Recog Coord Y1
[mm]", "Recog Coord X2 [mm]", "Recog Coord Y2 [mm]", "Fidu-
cial Mark FM1", and "Fiducial Mark FM2" text boxes for each unit.
• The recognition coordinates must be specified, regarding the
placement coordinate reference as an origin.
2.5 Placement Data
0305-001 2-47 AIL01EDTP

(C02_03) P-No.
Shown are the step Nos. of the placement data (P).
Set coordinates and angles for component placement in the lines of
the step Nos. (P-Nos.).
(C02_04) X [mm] and Y [mm]
Set coordinates X and Y for component placement.
The coordinates must be based on the placement coordinate refer-
ence point (N
0
).
Unit: mm
Fig. 3B98
(a) Do not set any coordinates for component placement in the last line
(last step No.).
Keep them as "000.000".
(b) To use the unit P.C.B. B.B.R. detection function (option), set the co-
ordinates of the bad mark to be put on in the "X [mm]" and "Y [mm]"
text boxes of the P-No. 1 step.
Refer to "3.5 Repetitive Patterns (Unit P.C.B. B.B.R. Function En-
abled) for concrete examples.
Y
X
Y
2
Y1
X1
X2
Placement Coordinate Reference (N0)
2.5 Placement Data
0305-001 2-48 AIL01EDTP
1
P-No.
Fig. 3B96
Fig. 3B97
X [mm]
Y
[mm]
010.000
010.000
Note