3OM-1003-005.pdf - 第241页

Stop time Shown is the period of time during which component placement operation is interrupted for component replenishment, etc. Error stop Error alarm Shown is the period of time during which an alarm (light tower ON) …

100%1 / 383
(14) Power on time
Shown is the time when the control power of the machine is ON.
Sample Display
10:03' 50"(10 hours, 3 minutes, 50 seconds)
Auto run time
Shown is the time when the machine was running automatically.
When a pattern program is set as the current one several times,
the sum total is computed.
Placement time
Shown is the time required to finish a P.C.B. (from first to last
component placement on a product P.C.B.).
The essential component placement time is summed up.
While the machine is set in the "STOP" or the "PAUSE"
mode or a step operation is performed, the time is not mea
sured.
This is used to calculate the average placement tact time
per component.
P.C.B. transfer time
Shown is the period of time during which each motor (motors
to drive the L conveyor, the transfer conveyor, the P.C.B. trans
fer, and the R conveyor) is being activated.
P.C.B. wait
Input wait
Shown is the time measured when the machine is completely
in the waiting mode (the machine is waiting for a P.C.B. to be
loaded from the input machine).
Output wait
Shown is the time measured when the machine is completely
in the waiting mode (the machine is waiting for a P.C.B. to be
unloaded to the output machine).
P.E.C./B.B.R.
Shown is the period of time during which the machine is taking
P.E.C. recognition and B.B.R. detection actions.
Counted is the period of time during which the X/Y table starts
moving and the P.E.C. recognition and B.B.R. detection are com-
pleted.
Others
Shown is the period of time during which the machine takes ac-
tions other than the above-described ones.
Included are the periods of time during which the F-axis takes
actions before component placement, the X/Y table returns af-
ter component placement, etc.
3.2 "Machine Performance Data" Tab
0403-002 4-16 AIL01EDTP
Note
Note
Stop time
Shown is the period of time during which component placement
operation is interrupted for component replenishment, etc.
Error stop
Error alarm
Shown is the period of time during which an alarm (light tower
ON) is issued.
Recovery
Shown is the time between error cancellation and restart of
machine operation.
Feeder Reload
Shown is the period of time during which components are sup-
plied.
Others
Shown is the period of time during which the machine performs
the set-up, program change, idling operations, etc.
(15) Maintenance time
Shown is the period of time during which the [OPERATION] switch
on the front operation panel is set to the "SETUP" side.
(16) Warm-up run time (Test Mode)
The running time is counted when the machine is operated under
the following condition.
"ENABLE" set for "TEST RUN" in "Run Mode" Tab Sheet ("OPN.
MODE" Window)
"PCB XFR Err Det Disabled" Check Box Checked
(State in which no P.C.B. is put in and out)
(17) Test mode time
Shown is the period of time during which test run is performed
according to the test mode parameters.
3.2 "Machine Performance Data" Tab
0403-002 4-17 AIL01EDTP
(18) Total handling errors/Total components
Shown are the total number of pick-up errors, the total number of
components to be picked up, and the percentage of pick-up er-
rors per total number of picked components.
A: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected by
the linear measure detection photosensor and the percentage of
component missing errors per total number of pick-up errors.
B: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected in
the recognition process and the percentage of component miss-
ing errors per total number of pick-up errors.
C: comp. vertical (% of Total handling errors)
Shown are the number of vertical components detected by the
linear measure detection photosensor and the percentage of ver-
tical component errors per total number of pick-up errors.
D: comp. recog. (% of Total handling errors)
Shown are the number of errors detected in the recognition pro-
cess and the percentage of errors per total number of pick-up
errors.
E: comp. thick (% of Total handling errors)
Shown are the number of errors in component thickness detected
by the linear measure detection photosensor and the percentage
of errors per total number of pick-up errors.
F: pick-up diff (% of Total handling errors)
Shown are the number of pick-up difference errors detected in
the recognition process and the percentage of the errors per total
number of pick-up errors.
G: comp. reverse (% of Total handling errors)
Shown are the number of reversed component errors detected in
the recognition process and the percentage of the errors per total
number of pick-up errors.
Total handling errors
Shown is the total number of pick-up errors.
1point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected on the first fiducial
mark and the percentage of the detected errors per total number
of all errors detected by the P.E.C. recognition function.
2point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected on the second
fiducial mark and the percentage of the detected errors per total
number of all errors detected by the P.E.C. recognition function.
3.2 "Machine Performance Data" Tab
0403-002 4-18 AIL01EDTP