3OM-1003-005.pdf - 第92页
Block When placement data is created to cope with the block sorting func- tion or the block-specified multi-model repetitive pattern function, the recovery regulation function must be enabled. "Block-Specified"…

(A01_15) C1 accel des, C2 accel des
Select one of the following options to determine acceleration of each
feeder carriage movement for component picks.
Full Speed 10%Decr 20%Decr 30%Decr
40%Decr 50%Decr 60%Decr 70%Decr
80%Decr 90%Decr
(A01_16) Recovery regulation
U-N
When placement data is created to cope with the Un-specified multi-
model repetitive pattern function, the recovery regulation must be en-
abled.
Refer to "2.1 Types of P.C.B.’s and Required Data" for de-
tailed information on how to specify "Un".
Disable : The recovery regulation function is disabled.
The normal automatic recovery function is activated.
Enable : The recovery regulation function is enabled.
When the automatic recovery function is activated, a pat-
tern with the smallest "Un" No. is recovered first and the
subsequent patterns are recovered in the ascending or-
der.
As long as all components in the pattern (smaller Un No.)
are not recovered, no components are placed on the sub-
sequent Un No. (Unit).
051 1-002 2-22
AIL01EDTP
2.3 Operation Data
Fig. 3B33
U
-N
Block
Disable
Disable
C1 accel des
Fig. 3B32
Full Speed
C2 accel des
Full Speed
Note

Block
When placement data is created to cope with the block sorting func-
tion or the block-specified multi-model repetitive pattern function, the
recovery regulation function must be enabled.
"Block-Specified" means that a control command (0 to 9) is
used for certain data in the placement data (P).
Disable : The recovery regulation function is disabled.
The normal automatic recovery function is activated.
Enable : The recovery regulation function is enabled.
When the automatic recovery function is activated, the
components in the group with the smallest block No. are
recovered first and the components in the subsequent
groups are recovered in the ascending order.
As long as all components in the group (smaller block
No.) are not recovered, the subsequent group of com-
ponents (block No.) are not placed.
(a) When "Enable" is set in the "U-N" or the "Block" text box,
the automatic (delayed) recovery function (priority of com-
ponents) cannot be used.
Even when the [Priority of Comp.] button is selected in
the "Opn. Mode" tab sheet of the "OPN. MODE" window
(submenu), it is automatically changed to the "Stop Auto
Run" mode.
(b) When "Enable" is set in the "Block" text box of the label
"Recovery regulation", it is invalidated unless the pattern
program is created to cope with the multi-model repeti-
tive pattern function or the block sorting function. This is
not regarded as an error during pattern program check
operation.
(c) When "Enable" is set in the "U-N" and the "Block" text
boxes, only "Enable" in the "Block" text box becomes
valid.
0305-001 2-23
AIL01EDTP
2.3 Operation Data
Note
Note

Sample Usage of This Function
• Use this function when the adjoining pitch of components is "0.4
mm" or less.
There is an effect to prevent the interference between the compo-
nents to be placed and the already-placed components and the in-
terference between the already-placed components and the nozzles
during component placement operation.
• Use this function when small components must be placed on the
placed large ones.
• Use this function when the shielding cases, etc., must be attached
to the placed components.
(A01_17) Unit P.C.B. B.B.R. (Option)
When the machine is not equipped with the unit
P.C.B. B.B.R. function (option), this function cannot
be used.
Mode
Set one of the following options to determine whether or not the unit
P.C.B. B.B.R. detection function should be used.
Disable : The unit P.C.B. B.B.R. detection function is
disabled.
Standard : The unit P.C.B. B.B.R. detection is made at
the standard position.
Optional : The unit P.C.B. B.B.R. detection is made at
an optional position.
(a) Standard
In the P-No. 1 step of the placement data (P), set the unit
P.C.B. B.B.R. detection mark position.
Refer to "(C02) Placement Data (P-data)" for details.
(b) Optional
Refer to "(C03) Placement Data (O-data)" for details.
051 1-002 2-24
AIL01EDTP
2.3 Operation Data
DisableMode
Fig. 3B34
Note
Note