*5 Input conveyor Timer #1 [sec], Timer #2 [sec], Stop timer [sec] Set each parameter to specify how the input conveyor should work. Timer #1 [sec] Set the time to limit the operating time (P .C.B. reception from the inp…

0305-001 5-57 AIL01EDTP
*4 Input mode
Select a parameter according to the P.C.B. unloading system of the
input machine.
Conveyor
The input conveyor is activated to receive a P.C.B. from the input
machine when the P.C.B. transfer signal is received from the input
machine.
When the P.C.B. transfer signal is interrupted, the input conveyor
stops running.
Pusher
The pusher of the input machine forces a P.C.B. out to the input
conveyor of the machine.
When the P.C.B. detection sensor (for the pusher) is not provided at
the inlet side of the input conveyor, do not set "Pusher" in the text
box.
SMEMA (Not Available)
P.C.B.’s are transferred according to the "SMEMA" standard.
Conveyer #2
The P.C.B. on the conveyor can be transferred only when a P.C.B.
request signal is received.
Conveyor #3
The input conveyor is activated to receive a P.C.B. from the input
machine when the P.C.B. transfer signal is received from the input
machine.
The input conveyor keeps on running even if the P.C.B. transfer sig-
nal is interrupted temporarily.
3.3 "Auto Operation" Tab

*5 Input conveyor
Timer #1 [sec], Timer #2 [sec], Stop timer [sec]
Set each parameter to specify how the input conveyor should work.
Timer #1 [sec]
Set the time to limit the operating time (P.C.B. reception from the
input machine) of the input conveyor.
This timer measures the operating time of the input conveyor and is
used to detect an interrupted P.C.B.
(a) Add 2 seconds (approx.) to the time required for P.C.B.
reception from the input machine and set the time in
the text box.
(b) The data input range is "0 to 99 seconds".
Timer #2 [sec]
Set the time to limit the operating time of the input conveyor to transfer
a P.C.B. on the main machine side.
This timer measures the operating time of the input conveyor and is
used to detect an interrupted P.C.B.
The data input range is "0 to 99 seconds"
Stop timer [sec]
Set the delay time (the period of time during which the sensor at the
buffer position of the input conveyor detects a P.C.B. and the con-
veyor stops) in the text box.
When a P.C.B. has a cutout as shown in the figure below and stops
at a position where the photosensor is located inside the cutout af-
ter it is detected by the photosensor, the system determines it as
there is no P.C.B. To avoid this, it is required to set the delay time.
Fig. 3E50
0305-001 5-58
AIL01EDTP
3.3 "Auto Operation" Tab
Photosensor
Cutout
P.C.B.
Note
Note

0305-001 5-59 AIL01EDTP
*6 Output mode
Select "Standard", "Interval", or "SEMEMA" to determine how to trans-
fer a P.C.B. from the main machine to the output machine.
Standard
When the output machine is manufactured by us, set "Standard" in
the text box.
When the work request signal is received from the output machine,
the P.C.B. transfer signal of the machine is turned ON and a P.C.B.
is transferred to the output machine by the output conveyor.
When the work request signal is not turned OFF within the specified
time after a P.C.B. unloading action has started, the machine stops
in an error condition.
Interval
When the work request signal of the output machine is turned ON,
P.C.B.’s on the machine side are transferred to the output machine.
The conveyor stops when the output conveyor timer has reached
the specified time.
The machine starts its unloading actions when the unloading condi-
tion is fulfilled after the conveyor has stopped running and the time
specified in the "Output interval timer [sec]" text box has elapsed.
No error detection is made.
SMEMA (Not Available)
P.C.B.’s are transferred according to the "SMEMA" standard.
*7 Output conveyor
Timer #1 [sec], Timer #2 [sec], Stop timer (Buffer #1) [sec], Stop
timer (Buffer #2) [sec]
Timer #1 [sec]
Set the time to limit the operating time (P.C.B. reception by the out-
put machine) of the output conveyor.
(a) Add 2 seconds (approx.) to the time required for P.C.B.
reception by the output machine and set the time in the
text box.
(b) The data input range is "0 to 99 seconds".
Timer #2 [sec]
Set the time to limit the operating time of the output conveyor to
transfer a P.C.B. on the main machine side.
The data input range is "0 to 99 seconds"
3.3 "Auto Operation" Tab
Note
Note
Note