3OM-1003-005.pdf - 第299页

*2 Offset [deg] The parameters are used to correct the variations in the origin posi- tions of the nozzles on each head. The difference between the master head and the reference value is automatically calculated through …

100%1 / 383
(1) "Head Origin" Tab Sheet
Sheet Layout
When the "Head Origin" tab is pressed in the "Head" tab sheet, the fol-
lowing tab sheet appears.
Fig. 3E20 "Head Origin" Tab Sheet
Sheet Composition
*1 Head
The head Nos. are displayed.
0305-001 5-19
AIL01EDTP
*1
*2
3.2 "Device Offset" Tab
*2 Offset [deg]
The parameters are used to correct the variations in the origin posi-
tions of the nozzles on each head.
The difference between the master head and the reference value is
automatically calculated through teaching operation.
Fig. 3E21
0305-001 5-20
AIL01EDTP
3.2 "Device Offset" Tab
(2) "Head Offset" Tab
Sheet Layout
When the "Head Offset" tab is pressed in the "Head" tab sheet, the
following tab sheet appears.
Fig. 3E22 "Head Offset" Tab Sheet
Sheet Composition
*1 Head
The head Nos. are displayed.
*2 X [mm], Y [mm]
This is the offset data for positional adjustment based on the #1
head position and used when a head other than the #1 head is at-
tached.
(a) It is not necessary to enter any parameter for the #1
head because it is selected as the reference head.
Note: The entered parameters are reflected as offset
values.
Use this function to adjust the head positions after
checking how components are placed.
(b) These parameters are used to correct positional de-
viations between heads caused by each head up/down
guide.
0305-001 5-21
AIL01EDTP
3.2 "Device Offset" Tab
*1 *2
Note