3OM-1003-005.pdf - 第94页

Image Select one of the following options to determine how to capture an image of the unit P .C.B. B.B.R. detection mark (bad mark). Black (E/NR) : A black mark (E/NR) is used. White (E/R) : A white mark (E/R) is used. C…

100%1 / 383
Sample Usage of This Function
Use this function when the adjoining pitch of components is "0.4
mm" or less.
There is an effect to prevent the interference between the compo-
nents to be placed and the already-placed components and the in-
terference between the already-placed components and the nozzles
during component placement operation.
Use this function when small components must be placed on the
placed large ones.
Use this function when the shielding cases, etc., must be attached
to the placed components.
(A01_17) Unit P.C.B. B.B.R. (Option)
When the machine is not equipped with the unit
P.C.B. B.B.R. function (option), this function cannot
be used.
Mode
Set one of the following options to determine whether or not the unit
P.C.B. B.B.R. detection function should be used.
Disable : The unit P.C.B. B.B.R. detection function is
disabled.
Standard : The unit P.C.B. B.B.R. detection is made at
the standard position.
Optional : The unit P.C.B. B.B.R. detection is made at
an optional position.
(a) Standard
In the P-No. 1 step of the placement data (P), set the unit
P.C.B. B.B.R. detection mark position.
Refer to "(C02) Placement Data (P-data)" for details.
(b) Optional
Refer to "(C03) Placement Data (O-data)" for details.
051 1-002 2-24
AIL01EDTP
2.3 Operation Data
DisableMode
Fig. 3B34
Note
Note
Image
Select one of the following options to determine how to capture an
image of the unit P.C.B. B.B.R. detection mark (bad mark).
Black (E/NR) : A black mark (E/NR) is used.
White (E/R) : A white mark (E/R) is used.
Component prechuck
"Enable" or "Disable" can be selected to determine whether or not
components should be prechucked.
Disable : Components are not picked up until the unit P.C.B.
B.B.R. detection is completed.
Enable : Components are picked up before the unit P.C.B.
B.B.R. detection is completed.
Sequence
Set one of the following options when both P.C.B. recognition and
unit P.C.B. B.B.R. detection functions are used together.
Bad Mark : The unit P.C.B. B.B.R. detection function is acti-
vated before the P.C.B. recognition function. No
recognition is implemented on the unit P.C.B.
where a bad mark is put.
Recognition: The P.C.B. recognition function is activated before
the unit P.C.B. B.B.R. detection function. Positional
correction is made according to the result of the
P.C.B. recognition during movement to the bad
mark position.
0305-001 2-25
AIL01EDTP
2.3 Operation Data
EnableComponent prechuck
Fig. 3B36
Black (E/NR)
Image
Fig. 3B35
Bad Mark
Sequence
Fig. 3B37
Fig. 3B39
X (horizontal)[mm]
Y (vertical)[mm]
000.00
000.00
(A01_18) Overall P.C.B. B.B.R. (Option)
When the machine is not equipped with the unit P.C.B.
B.B.R. function (option), this function cannot be used.
Mode
Select one of the following options for the overall P.C.B. B.B.R.
function.
Disable : The overall P.C.B. B.B.R. detection function is not
used.
Enable : The overall P.C.B. B.B.R. detection function is used.
X (horizontal) [mm] and Y (vertical) [mm]
When "Enable" is selected, the coordinates (X and Y) of the bad
mark should be set for the overall P.C.B. B.B.R. detection function.
Unit: mm
051 1-002 2-26
AIL01EDTP
2.3 Operation Data
Disable
Mode
Fig. 3B38
Note