B: comp. missing (% of T otal handling errors) Shown are the number of component missing errors detected in the recognition process and the percentage of component missing errors per total number of pick-up errors. C: co…

100%1 / 383
Stop time
Shown is the period of time during which component placement
operation was interrupted for component replenishment, etc.
Error stop
Error alarm
Shown is the period of time during which an alarm (light
tower ON) is issued.
Recovery
Shown is the time between error cancellation and restart
of machine operation.
Feeder Reload
Shown is the period of time during which components are
supplied.
Others
Shown is the period of time during which the machine per-
forms the set-up, program change, idling operations, etc.
(16) Maintenance time
Shown is the period of time during which the [OPERATION]
switch on the front operation panel was set to the "SETUP" side.
(17) Warm-up run time
The running time is counted when the machine is operated un-
der the following condition.
"ENABLE" set for "TEST RUN" in "Run Mode" Tab Sheet ("OPN.
MODE" Window)
"PCB XFR Err Det Disabled" Check Box Checked
(State in which no P.C.B. is put in and out)
(18) Test mode time
Shown is the period of time during which test run is performed
according to the test mode parameters.
(19) Total handling errors/Total components
Shown are the total number of pick-up errors, the total number
of components to be picked up, and the percentage of pick-up
errors per total number of picked components.
A: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected
by the linear measure detection photosensor and the percent-
age of component missing errors per total number of pick-up
errors.
4.2 "Machine Performance Data" Tab
0403-002 4-37 AIL01EDTP
B: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected
in the recognition process and the percentage of component
missing errors per total number of pick-up errors.
C: comp. vertical (% of Total handling errors)
Shown are the number of vertical component errors detected by
the linear measure detection photosensor and the percentage
of vertical component errors per total number of pick-up errors.
D: comp. recog. (% of Total handling errors)
Shown are the number of errors detected in the recognition pro-
cess and the percentage of errors per total number of pick-up
errors.
E: comp. thick (% of Total handling errors)
Shown are the number of errors in component thickness de-
tected by the linear measure detection photosensor and the per-
centage of errors per total number of pick-up errors.
F: pick-up diff (% of Total handling errors)
Shown are the number of pick-up difference errors detected in
the recognition process and the percentage of the errors per
total number of pick-up errors.
G: comp. reverse (% of Total handling errors)
Shown are the number of reversed component errors detected
in the recognition process and the percentage of the errors per
total number of pick-up errors.
Total handling errors
Shown is the total number of component handling errors.
1point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected on the first fidu-
cial mark and the percentage of the detected errors per total
number of all errors detected by the P.E.C. recognition function.
2point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected on the second
fiducial mark and the percentage of the detected errors per total
number of all errors detected by the P.E.C. recognition function.
4.2 "Machine Performance Data" Tab
0305-001 4-38 AIL01EDTP
0305-001 4-39 AIL01EDTP
4.2 "Machine Performance Data" Tab
3point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected o the third fiducial
mark and the percentage of the detected errors per total num-
ber of all errors detected by the P.E.C. recognition function.
Local fiducial errors (% of Total P.E.C. recog. errors)
Shown are the total number of individual P.E.C. recognition er-
rors and the percentage of the detected errors per total number
of all errors detected by the P.E.C. recognition function.
Total P.E.C. recognition errors
Shown is the total number of errors detected by the P.E.C. rec-
ognition function.
The number of errors detected by the global P.E.C. recognition
function and the total number of errors detected by the B.B.R.
recognition function are displayed.
*2 Vertical Scroll Bar
Scroll arrows are located at both ends of a scroll bar. The up or the
down arrow can be pressed to scroll up or down a tab sheet to
expose hidden items.