: When pressed, the "Nozzle T ype Property" window opens, enabling the operator to add a new nozzle type. This function is available only in the "Nozzle Data" tab sheet. : When pressed, this button de…

• Composition of "Nozzle Data" Window
Fig. 3E7 "Nozzle Data" Window
*1 Icons
The following functions can be executed.
: When pressed, this icon closes the "Nozzle Data" win-
dow.
: When pressed, this icon saves the entered parameters.
: When pressed, this icon checks the entered parameters.
When an error is found, an error message box opens.
: When pressed, this icon opens the "Nozzle Type" win-
dow.
This window enables you to change the currently selected
nozzle type to another one.
(a) Double-clicking a text box also opens the "Nozzle
Type" window.
(b) Clicking a "Nozzle #" label (title) selects the nozzle
Nos. on all heads at a time.
0305-001 5-7
AIL01EDTP
2.1 Display of Each Window
*1
Note
Note

: When pressed, the "Nozzle Type Property" window opens,
enabling the operator to add a new nozzle type.
This function is available only in the "Nozzle Data" tab sheet.
: When pressed, this button deletes the selected nozzle
type.
This function is available only in the "Nozzle Data" tab sheet.
: When pressed, this button opens the "Nozzle Type Prop-
erty" window for the selected nozzle type, enabling the
operator to change the nozzle type.
This function is available only in the "Nozzle Data" tab sheet.
: When pressed, this icon fills all the selected text boxes
with the parameter in the first text box.
: When pressed, this icon fills all the selected text boxes
with the parameter in the last text box.
: When pressed, this icon initializes the selection (sets the
defaults).
0305-001 5-8
AIL01EDTP
2.1 Display of Each Window
Note
Note
Note

2.1.3 "MACH SETUP" Window
The following describes how to open the "MACH SETUP" window.
• Window Layout
(1) Press the [SYSTEM] button on the main menu bar. The "SYS SEL"
menu opens.
Fig. 3E8
(2) Press the [MACH SETUP] button. The "MACH SETUP" window
opens.
Fig. 3E9 "MACH SETUP" Window
0305-001 5-9
AIL01EDTP
2.1 Display of Each Window